2 year warranty CE
  • 2% RH Accuracy
  • Easy to Install/Calibrate
  • Rugged Design
  • User Selectable Outputs
  • Reliable Sensor Technology
  • Outside Air, Room, Duct Mount Models Available

商品説明

The HX95 series RH/temp transmitters offer superior versatility, reliability, and performance in three models consisting of a low profile space mount, duct mount, and outside air mount model. Prewired base and plug-in electronics in the cover make installation quick and easy. Wiring is connected to the terminal block in the base and the cover can be snapped into place at a later time, allowing the user to mount and wire the unit without the sensor and electronics.

Outputs available are either 4-20 mA, 0-5 Vdc, or 0-10 Vdc. The voltage output unit is jumper selectable for either 0-5 Vdc or 0-10 Vdc, all models are available with either 2% or 3% RH accuracy. Typical drift is less than 1% per year and all models can be quickly field calibrated using the HX95-CAL handheld one point RH calibrator. Just plug the HX95-CAL into the phone jack connector on the transmitter. The HX95-CAL displays the RH reference environment as well as the transmitter RH reading during calibration. A quick one point offset adjustment allows calibration in about 60 seconds without interrupting transmitter operation.

The HX95, HX96, HX97 transmitters as well as the HX95-CAL feature a bulk polymer resistive sensor which will not be affected by surface contamination in dirty environments. As a result, you can expect long term stability with minimal drift. The HX97 outside air model is designed in a rugged case with the probe housed in an aluminum sheath allowing for uniform air flow, making it ideal for applications requiring a rugged RH transmitter to monitor outside air RH and temperature.
注文する (部品番号ビルダーより掲載以外の製品もご選択いただけます)(注文数を入力の上、"カートに追加"をクリックしてください)

他のお客様はこのような商品も購入しています。: このアイコンをクリックすると、このモデルを購入した他のお客様の購入商品リストが表示されます.

部品番号/Desc.
注文数
商品説明
  
HX96-2-C-D
お問い合せ下さい   
納期: 
 
 
Duct Mount RH/temperature transmitter with current output and 2% accuracy
Click to expand/minimize a list of what others bought with theTX4-100
TX4-100
¥14,568 (税込)
(税抜価格 ¥13,244)
納期: 2 週間
 
4 conductor shielded transmitter cable (100ft)
Click to expand/minimize a list of what others bought with theCAL-3-HU
CAL-3-HU
お問い合せ下さい   
納期: 
 
 
NIST Traceable Calibration
We noticed you are from the US. Visit your local site for regional offers and live support.