High Performance Talking Digital Multimeter - Dual Input Thermometer & Infrared Pyrometer
Product No Longer Available

HHM2A-IR

Talking  Digital Multimeter - Dual Input Thermometer Infrared Pyrometer | HHM2A-IR

スクロールダウンし、全ラインアップをご覧ください

2 year warranty
  • Non-Contact IR Temperature Measurement Pyrometer Circle/Dot Combined Temperature
  • Built-in Laser Sighting
  • Voice Annunciation of Measured Parameters in a Choice of 5 Languages
  • Dual Type K Thermocouple Inputs With Differential Measurements Actual Display Size!
  • 0.25 % Basic dc Accuracy
  • True RMS ac Measurement
  • 4 Digit Temperature Display, 33/4 Digit DMM Display
  • 0.1° Resolution to 1000°
  • Continuous or Manual Button Control of Voice Annunciation

商品説明

This Product is NO LONGER AVAILABLE!

The new OMEGASAYS® digital multimeter/ thermometer/IR Pyrometer is a full function digital multimeter which also features non-contact infrared temperature measurement, dual type K thermocouple inputs and voice annunciation of measured values. This compact, portable meter measures true RMS ac voltage and current, as well as resistance and temperature, and will accept any two type K thermocouples terminated with miniature SMP connectors. The HHM1-IR features a standard voice annunciation used to verbally tell the user the current measurement in a choice of five different languages. The OMEGASAYS® displays measured values on an easy to read LCD for visual indication, which also includes an indication of the current measurement function, the other available measurement functions, speech function status (continuous, on demand or off), measurement units, thermocouple probe input (T1, T2 or T1-T2), display hold and low battery. All DMM connections plug into the front of the unit. Thermocouples, pyrometer module, earphones and the ac adaptor plug into the rear panel of the unit, which also contains a three-position volume selector switch. On top of the HHM1-IR meter is an on/off switch along with six pushbuttons to select from among a variety of unique additional functions. These include a “TEMP” function, which selects IR/thermocouple input T1, T2 or the differential. The “. ZERO” function compensates for the resistance of the test leads when taking resistance measurements. “DISPLAY HOLD/SPEAK” selects continuous or on-demand speech or freezes the display. The “SPEECH” button turns the speech function on and off. “°F/°C” switches the temperature units. “AC/DC” similarly switches between ac and dc measurements. Included with each HHM1-IR is a set of test leads for measuring voltage, current and resistance. The red lead handle includes a convenient pushbutton to easily operate the speech function while holding the leads. An optional pistol grip type K thermocouple handle is also available with a similar pushbutton to activate the voice function remotely for temperature measurements.

Meter Specifications
Power Supply: 9 V battery or 110 Vac adaptor (included)
Battery Life: Approx. 150 hrs/no speech/approx., 30 hrs continuous speech; alkaline battery Ambient Operating Conditions: 32 to 122°F (0 to 50°C); 0 to 80% RH
Storage Temperature: 14 to 140 °F (-10 to 60 °C)
Dimensions: 2.36 H x 3.15 W x 6.69" D (6 x 8 x 14 cm)
Weight: 18 oz (0.5 kg), including battery, fuses, speech module

Current Measurement
RangeResolutionAccuracy
dcac
400 mA0.1 mA±0.5% ±2 d±2% ±2 d
4 A1 mA±1% ±2 d±2% ±2 d
Note: ac bandwidth is 50 to 20 kHz; 50 Hz to 5 kHz for signals > 40 mA in
400 mA range, for signals < 0.4 A in 4 A range. Spectral Response: 8 to 14 microns

Ranges: The 400 mA and 4 A current ranges have separate, individually fused inputs.

Type-K Temperature Measurement
RangeResolutionAccuracy
HHM2HHM2A
-200 to -150°C0.1°C±12°C±1.5°C
±3.0°F
-328 to -238°F0.2°F±24°F
-150 to -100°C0.1°C±6.0°C±1°C
-238 to -148°F0.2°F±12°F
-100 to -50°C0.1°C±3.0°C
-148 to -58°C0.2°F±6.0°F
-50 to 0°C0.1°C±1.5°C
-58 to 32°F0.2°F±3.0°F
0 to 999°C0.1°C±1.0°C
32 to 999°F0.2°F±2.0°F
1000 to 1372°C1°C±1°C
1000 to 2502°F1°F±2°F
Functions: Dual input, with differential measurement capability (T1, T2, T1-T2)
Input Type: Type K thermocouple Units: User selectable °F or °C
Input Protection: 24 V rms or 60 Vdc max. input voltage on any combination of input pins
Common Mode Voltage: 0.5 V max., between T1 and T2 during measurement

Voltage Measurement
RangeResolutionAccuracy
dcac
400 mV0.1 mV±0.25%
±2 digits
±0.25%
±2 digits
4 V1 mV
40 V10 mV
400 V100 mV
1000 Vdc/
750 Vac
1 V

Resistance Measurement
RangeResolutionAccuracy
400 Ω0.1 Ω±0.25% ±2 digits
4 kΩ1 Ω
40 kΩ10 Ω
400 kΩ100 Ω
4 MΩ1 kΩ
40 MΩ10 kΩ±0.5% ±2 digits
Input Protection: 400 mA/250 V fast acting fuse, 400 mA range;
4 A/250 V fast acting fuse, 4 A range
Input Protection: 250 V rms ac or dc
Autoranging: Unit autoranges over all six ranges
Digital Ohms Zero: Nulls out test lead impedance for low resistance
readings in the 4000 . range

Non-Contact Infrared Specifications
Temp Range: -18 to 538 °C (0 to 1000 °F)
Accuracy: ±3% of Reading or 2.2 °C (4 °F)
Repeatability: ±1% of Reading
Spectral Response: 8 to 14 microns
Optical Field of View: 6:1 (Distance/Spot Size)
Response Time: 150 msec (0 to 63% of final value)
Emissivity: Adjustable from 0.1 to 1.00
Analog Output: K-type Thermocouple (Compensated)
Output Connection: (Universal Type-K Female) accepts both miniature and standard male Type-K connectors
Power: 3.5V Lithium Battery, (AA), 1900mAh
Low Power Indicator: Flashing LED
Ambient Operating Conditions: 32 to 122°F (0 to 50°C); Less than 95% RH (Non-Condensing)
Dimensions: 2.5 x 5 x 10 cm (1" h x 2" w x 4" d)
Weight: 100 g (0.22 lbs)
Sighting Type: Built-In laser (Circle/Dot Combined) Laser Wavelength (Color): 630-670 nm (Red)
Max Laser Power: Less than 1 mW Safety Classification: Class 3A
Beam Diameter: 5 mm
Beam Divergence: Less than 2 mrad
Laser Power Switch: Momentary
Laser Power Indicator: Flashing Red LED

THIS PRODUCT IS NOT INTENDED FOR USE BY THE VISUALLY IMPAIRED.