3 year warranty CE
  • Universal Sensor Inputs: Thermocouple, 3-Wire RTD or DC Linear (mA, mV or V)
  • Autotune on Soaks and Basic Process Control
  • Remote and Local Program Number Select, Run, Hold, and Abort
  • 90 to 264 Vac Power Supply
  • Dual 4-Digit Programmable Display and Alphanumeric Message Display
  • End of Program Relay Output
  • Eight Programs, 16 Segments with Program Joining
  • Readable Run Time Messages
  • Assured Soak
  • NEMA-4/IP65 Sealed Front Panel

    Optional Features
  • Low Voltage Power Supply: 20 to 50 Vac/ 22 to 65 Vdc
  • RS-485 Communications
  • Remote Inputs, Event Outputs
  • Real Time Clock

商品説明



TheCN1460 Series is no longer available. Please see the CN8240/ CN8260 Series as a substitute or contact Sales/Temperature Engineering.

The OMEGA™ CN1462 is a 1/4 DIN microprocessor-based, single loop process controller with programmable setpoint profile programs. It can function either as a basic process controller, utilizing manual setpoint changes, or it can execute any one of eight setpoint programs. Each program is adjustable in the range of 1 to 16 segments, cascadable to a maximum length of 121 segments. Each segment can be a ramp, a soak, a join, or an end. A delayed start feature is standard, as is an end of program relay. By using the auto hold feature, assured soaks are possible. The unit can include two 4-20 mA current outputs which can be used for control and a third current output to be used for retransmission. In lieu of current control outputs, relays or dc pulse outputs are available. Four (4) relay event outputs are available as an option. The CN1462 is used to control or program temperature or other process variables in a variety of applications.

Examples of pricing for popular models is referenced in the "To Order" box. Use the "Part Number Builder" below to get pricing for all available models.
For complete product specifications see the Related Links section at the bottom of this page.
注文する (部品番号ビルダーより掲載以外の製品もご選択いただけます)(注文数を入力の上、"カートに追加"をクリックしてください)
部品番号/Desc.
注文数
商品説明
CN1462-DC1-4
お問い合せ下さい   
納期: 
 
 
Ramp/soak profile controller with dc pulse output and real time clock
CN1462-R1-DC2-XP3
お問い合せ下さい   
納期: 
 
 
Ramp/soak profile controller with relay output and excitation power
CN1462-R1-R2-DC3-LV-C4
お問い合せ下さい   
納期: 
 
 
Ramp/soak profile controller with two relay outputs, dc pulse output, 20-50 Vac/22-65 Vdc power, 20-27 Vdc excitation power and RS-485 communications
CN1462-R1-R2-XP3-LV-C4
お問い合せ下さい   
納期: 
 
 
Ramp/soak profile controller with two relay outputs, 20-27 Vdc excitation power, 20-50 Vac/22-65 Vdc power, and RS-485 communications
BD1600-R
お問い合せ下さい   
納期: 
 
 
Field Installable 2 A relay board
BD1600-DC
お問い合せ下さい   
納期: 
 
 
Field Installable dc pulse output board
BD1600-F
お問い合せ下さい   
納期: 
 
 
Field Installable analog output board
BD1600-C4
お問い合せ下さい   
納期: 
 
 
Field Installable RS-485 Communications board
BD1600-XP
お問い合せ下さい   
納期: 
 
 
Field Installable transmitter power supply board
注: The single output models are standard. To order two or three outputs, specify output suffix from the Second and Third Output Options tables.

部品番号ビルダー

下記から仕様構成を選択し、ご注文ください
以下からオプションを選択:


(1) Base Models :
CN1462-R1 : Single relay output profile controller
CN1462-DC1 : Single dc pulse output profile controller
CN1462-F1 : Single analog output profile controller

(2) Second Output Options :
オプション選択がない場合 : Standard Unit
-R2 : Relay
-DC2 : dc pulse
-F2 : Analog (control only)
-XP2 : Transmitter power supply

(3) Third Output Options :
オプション選択がない場合 : Standard Unit
-R3 : Relay
-DC3 : dc pulse
-F3 : Analog (retransmission only)
-XP3 : Transmitter power supply

(4) Low Voltage Power Supply Option :
オプション選択がない場合 : Standard Unit
-LV : 20 to 50 Vac / 22 to 65 Vdc

(5) RS-485 Communications Option :
オプション選択がない場合 : Standard Unit
-C4 : RS-485 communications

(6) Additional Options (Only 1 option available per unit) :
オプション選択がない場合 : Standard Unit
-1 : 4 event outputs
-2 : 6 remote profile control inputs
-3 : 4 event outputs and 6 remote profile control
-4 : Real time clock
-5 : Real time clock and event outputs
-6 : Real time clock and event inputs
-7 : Real time clock and event outputs and
注: 有効な部品番号については、「商品仕様(PDF)」を参照ください。