フリーダイヤル 0120-769-103
Emailjpesales@dwyeromega.com

1/8 DIN 1/4 DIN, 68mm Sq Cutout Temperature
and Process Autotune Controllers
Models: CN134, CN147, CN138
Discontinued Product!

CN130 Family

Temperature and  Process Autotune Controllers 1/8 DIN 1/4 DIN | CN130 Family

スクロールダウンし、全ラインアップをご覧ください

1 year warranty CE
  • Dual display - Process and Setpoint
  • Easy Programming from Front Panel
  • Display Accuracy: 0.3% FS + 1 Digit
  • Low Voltage Power Options: 24 Vac/dc
  • CSA Listed

    INPUTS
  • Accepts 12 Types of Thermocouple, 2 RTD Types, 14 Voltage and Current Input Ranges
  • Includes Platinel ll & Type C Thermocouple plus DIN & JIS RTD Inputs
  • Isolation of Inputs and Outputs

    OUTPUTS
  • Relay, dc Pulse, Voltage or Current Output
  • Single Event Output Option
  • Absolute or Deviation Alarms
  • Analog Output: Transmits Either the PV or Setpoint to a Remote Recording, Computing or Indicating Device

    CONTROL OPTIONS
  • Autotune PID or On/Off Control
  • Ability to Scale Linear mV, V or mA dc Inputs to Corresponding Engineering Units Within -1999 to 9999 Range (Decimal Point Programmable Within Same Range)
  • Provides Set Value Bias (Alternative Idle Setpoint Initiated by Contact Closure)

商品説明



TheCN134, CN137, and CN138 Series are no longer available. Please see the CN8240/ CN8260 Series as a substitute or contact Sales/Temperature Engineering.

The CN130 family of controllers feature an advanced autotuning PID equation which automatically selects the optimum PID values, as well as offering the user the alternative of manually selecting the PID parameters. Units are available with either a mechanical relay, SSR driver, current or voltage outputs. When relay or SSR driver output models are specified, the user can configure the controller for on-off control. The optional alarm packages offer alarm points that can be set to any value within the input range. These setpoints can be selected by the user as either absolute or deviation alarms. To restrict unauthorized changes of control parameters, a four-level keylock feature is included.

The CN130 Series temperature and process controllers are available for thermocouple, RTD, voltage or current inputs. Thermocouple and RTD models allow the user to select from 12 thermocouple types or 2 RTD calibrations. Voltage and current input models allow the user to program the scaling and decimal point within the range of -1999 to 9999 units. The span can be programmed to a minimum of 100 units and a maximum of 5000 units.

Examples of pricing for popular models is referenced in the "To Order" box. Use the "Part Number Builder" below to get pricing for all available models.

For Special Options Consult Sales or Temperature Engineering for Availability and Pricing.
注文する (部品番号ビルダーより掲載以外の製品もご選択いただけます)(注文数を入力の上、"カートに追加"をクリックしてください)
部品番号/Desc.
注文数
商品説明
CN134MA-DC
お問い合せ下さい   
納期: 
 
 
1/4 DIN controller, programmable mA input and dc pulse output
CN134MV-V-HB2
お問い合せ下さい   
納期: 
 
 
1/4 DIN controller, programmable millivolts input, 0 to 10 Vdc voltage output, 50 A heater break alarm *
CN134RTD-F-AL1
お問い合せ下さい   
納期: 
 
 
1/4 DIN controller, RTD input, 4 to 20 mA output, hi/lo alarms
CN137MV-DC-AL1
お問い合せ下さい   
納期: 
 
 
68 mm square cutout controller, programmable millivolts input, dc pulse output and hi/lo alarms
CN137V-R-ALHB2
お問い合せ下さい   
納期: 
 
 
68 mm square cutout controller, programmable voltage input, mechanical relay output, hi/lo alarms and 50 A heater break alarm *
CN137TC-DC-SVB-LV1
お問い合せ下さい   
納期: 
 
 
68 mm square cutout controller, thermocouple input, dc pulse output, 24 Vac power, set value bias
CN138MA-V-SVB
お問い合せ下さい   
納期: 
 
 
1/8 DIN vertical controller, programmable mA input, 0 to 10 Vdc voltage output, and set value bias
CN138MV-DC-LV2
お問い合せ下さい   
納期: 
 
 
1/8 DIN vertical controller, programmable millivolts input, dc pulse output and 24 Vdc power
CN138TC-R-HB2-LV1
お問い合せ下さい   
納期: 
 
 
1/8 DIN vertical controller, thermocouple input, mechanical relay output, 30 A heater break alarm*, 24 Vac power
注:
* Heater break alarms not available with F or V output types.

部品番号ビルダー

下記から仕様構成を選択し、ご注文ください
以下からオプションを選択:


(1) PID Controllers :
CN134 : 1/4 DIN controller
CN137 : 68 mm square controller
CN138 : 1/8 DIN vertical controller

(2) Input Types :
MA : Programmable mA input
MV : Programmable millivolts input
RTD : RTD input
TC : Thermocouple input
V : Programmable voltage input

(3) Output Types :
DC : dc pulse
DC-LV1 : dc pulse with 24 Vac
DC-LV2 : dc pulse with 24 Vdc
F : 4 to 20 mA
F-LV1 : 4 to 20 mA with 24 Vac
F-LV2 : 4 to 20 mA with 24 Vdc
R : Mechanical relay
R-LV1 : Mechanical relay with 24 Vac
R-LV2 : Mechanical relay with 24 Vdc
V : 0 to 10 Vdc
V-LV1 : 0 to 10 Vdc and 24 Vac power
V-LV2 : 0 to 10 Vdc and 24 Vdc power

(4) Options :
オプション選択がない場合 : Standard Unit
-AL1 : Hi/Lo alarms
-AL2 : Hi/Lo alarms with one event
-HB1 : Heater break alarm* for heaters taking up to 30 A
-HB2 : Heater break alarm* for heaters taking up to 50 A
-ALHB1 : Hi/Lo alarms with heater break alarm* for heaters taking up to 30 A
-ALHB2 : Hi/Lo alarms with heater break alarm* with heaters taking up to 50 A
-PV1 : Recorder output of 0 to 10 Vdc & Load current of 2 mA dc max
-PV2 : 4 to 20 mA dc with Load resistance of 300 ohms max
-PV3 : 0 to 20 mA dc with Output resistance of 10 ohms
-SVB : Set value bias

(5) Power Options :
オプション選択がない場合 : Standard Unit
-LV1 : 24 Vac
-LV2 : 24 Vdc
注: 有効な部品番号については、「商品仕様(PDF)」を参照ください。
ご不明な場合は、カスタマーサービス(0120-040-572 もしくは jpesales@dwyeromega.com)へお問合せください。
We noticed you are from the US. Visit your local site for regional offers and live support.