フリーダイヤル 0120-769-103
Emailjpesales@dwyeromega.com

CL530

Milliamp Loop Calibrator | CL530

Milliamp Loop Calibrator

スクロールダウンし、全ラインアップをご覧ください

  • Source, Measure, Simulate, Read all 4-20 mA Process Loop Functions
  • Check 4 and 20 mA Span Limits
  • One-Handed Operation with Hands-Free Stepping/Ramping
  • Display mA or %
  • 0.012% Accuracy.
校正器 - 関連する商品を探す
(見つからない場合はカスタマーサービスにご連絡ください)

商品説明

The CL530 builds on OMEGA’s 30 years of calibration experience. The user can check, calibrate, and troubleshoot 4 to 20 mA process control loops with this easy-to-use instrument.

The CL532 has all the features of the CL530, plus it will read up to 30 Vdc and source up to 24 Vdc.

SPECIFICATIONS
Accuracy: ±0.012% rdg + 0.004 mA
Temperature Effect: ±50 ppm/°C
Operating Temperature Range: -20 to 60°C (-5 to 140°F)
Storage Temperature Range: -30 to 60°C (-22 to 140°F)
Relative Humidity Range: 10% ≤RH ≤90% [0 to 35°C (32 to 95°F)], non-condensing; 10% ≤RH ≤70% [35 to 60°C (95 to 140°F)], non-condensing
Overvoltage Protection: 120 Vrms for 30 seconds, 240 Vrms for 15 seconds
Overload Protection: 24 mA nominal
Battery: 9V, alkaline (included)
Battery Life:
    Source Mode: ≥18 hours at 12 mA (HartR disabled)
    Power Measure: 10 hours, read, 2 W limit sim.
Read Vdc: >40 hours
Loop Drive Ability: 1200 Ω at 20 mA for life of battery
Loop Burden: <2V at 20 mA Loop Supply Limits (2 W Limit Sim.): 2 to 60 Vdc
Connection: Alligator test leads attached, 610 mm (24") long
Dimensions: 84 W x 180 H x 56 mm D (3.3 x 7.1 x 2.2")
Weight: 326 g (11.5 oz)
Source Current: Source 0 to 24 mA or -25 to 125% into ≤1200 Ω; a flashing HIGH Ω indicator appears if improperly connected
2-Wire Transmitter Simulate: Adjust loop current from 0 to 24 mA or -25 to 125% when powered by an external supply; LOW SUPPLY flashes to indicate a misconnection
Power Measure: Power the loop and read 0 to 24 mA or -25 to 125%; CURRENT LIMITED flashes at >24 mA, protecting devices in the loop
Read Current: Read 0 to 24 mA or -25 to 125%; CURRENT LIMITED flashes at >24 mA, protecting devices in the loop
Read DC Voltage: Read 0 to 60 Vdc with 2x overrange ability and flashing OVERRANGE indicator
EZ-Check Switch: Gives instant access to 4 and 20 mA or other user-set span limits; in read modes, the EZ-Check switch provides a max/min log of reading
EZ-Step Button: Allows one-handed stepping up and down the span in 6 different step sizes
EZ-Dial Knob: Adjusts output by 0.001 mA (0.01%); push and turn for 100x faster adjustment—by 0.100 mA (1.00%)
注文する (部品番号ビルダーより掲載以外の製品もご選択いただけます)(注文数を入力の上、"カートに追加"をクリックしてください)

他のお客様はこのような商品も購入しています。: このアイコンをクリックすると、このモデルを購入した他のお客様の購入商品リストが表示されます.

部品番号/Desc.
注文数
商品説明
Click to expand/minimize a list of what others bought with theCL532
CL532
¥380,435 (税込)
(税抜価格 ¥345,850)
納期: 7 週間
 
Milliamp/Voltage calibrator
Accessories
  
CL530-ADAPTOR-220
¥33,336 (税込)
(税抜価格 ¥30,305)
納期: 2 週間
 
220 AC ADAPTOR FOR CL530/32
  
CL530-ADAPTOR
¥25,003 (税込)
(税抜価格 ¥22,730)
納期: 2 週間
 
110 AC adaptor
Click to expand/minimize a list of what others bought with theSC-530
SC-530
お問い合せ下さい   
納期: 
 
 
Rugged carrying case
注: The CL530 comes complete with test leads, operator’s manual, 9V alkaline battery and NIST calibration certificate.

製品マニュアル:

ダウンロード CL532 - ma/v Loop Calibrator
ダウンロード CL530 - 4-20 Milliamp Loop Calibrator
We noticed you are from the US. Visit your local site for regional offers and live support.