フリーダイヤル 0120-769-103
Emailjpesales@dwyeromega.com

Long Range Wireless Transmitters  - Discontinued

UWXL Series

Long Range Wireless Transmitters | UWXL Series

Long Range Wireless Transmitters

¥109,520 UWXL-24-TC

1 year warranty
  • Thermocouple, RTD, Infrared Temperature, RH, pH, Process Voltage/Current and Flow/Pulsed Frequency Input Models
  • J, K, T, E, R, S, B, and N Thermocouples
  • 385 and 392 Pt100 RTD Probes
  • IP68 Rated Industrial Enclosure
  • Free Software Converts Your PC Into a Multi-Channel Chart Recorder or Data Logger
  • Compatible with Both UWTC-REC and UWTC-REC-NEMA Wireless Receivers
  • Long Battery Life
ワイヤレス / 無線 - 関連する商品を探す
(見つからない場合はカスタマーサービスにご連絡ください)

商品説明

The UWXL series has been discontinued. Please contact our Electronic Engineering department.

The UWXL Series industrial wireless transmitters from OMEGA offer unparalleled flexibility for process measurement applications. Capable of ranges to 450 m (1500') line of sight (LOS), the UWXL transmitters are designed for a variety of applications, including temperature, infrared temperature, relative humidity, process transducers with standard voltage or current outputs as well as pH. Thermocouple models are user configurable for any of 9 calibrations, while RTD units are compatible with both 0.00385 and 0.00392 curve Pt100 sensors.

UWXL transmitters are programmable to transmit data at intervals configurable from once every 2 seconds to every 2 minutes. Transmitted data includes the process measurement along with the ambient temperature, RF signal strength and battery condition. Software provided with each model can display this information in real time. This free software allows you to use your PC as a multi-channel meter, recorder or data logger; data can also be exported to a standard spreadsheet file.

UWXL transmitters are compatible with a wide variety of OMEGA wireless receivers. UWTC-REC receivers are available with optional analog output, alarms and display, while the UWTC-REC-NEMA receivers add a NEMA rated enclosure. Receivers can accept up to 48 transmitters. Receivers with analog outputs can also retransmit data through a wired connection, as an analog voltage, current or thermocouple signal, to interface with a controller, PLC or data acquisition interface.

SPECIFICATIONS
Common Specifications
Computer Interface: USB
Transmit Sample Rate: Programmable from 2 sec to 120 sec
Radio Frequency (RF) Transceiver Carrier: ISM 2.4 GHz, direct sequence spread spectrum, (2.450 to 2.490 GHz - 12 RF channels)
RF Output Power: 18 dBm (63 mW)
Range of RF Link: Up to 450 m (1500 ft) outdoor line of sight; up to 90 m (300 ft) indoor/urban
RF Data Packet Standard: IEEE 802.15.4, open communication architecture
Software (Included Free): Requires Windows® 2000, XP or Vista (32 bit) operating system
Power: One 3.6V, Lithium C Cell (included)
Battery Life (Typical): 3 years; at 1 sample/minute reading rate @ 25°C
Operating Temperature: -10 to 70°C (14 to 158°F)
Storage Temperature: -40 to 80°C (-40 to 176°F)

MODEL UWXL-24-TC
Input: J, K, T, E, R, S, B, C or N thermocouple, software selectable
Measurement Range:
  J: -100 to 760°C (-148 to 1400°F)
  K: -100 to 1260°C (-148 to 2300°F)
  T: -200 to 400°C (-328 to 752°F)
  E: -200 to 1000°C (-328 to 1832°F)
  R: 260 to 1760°C (500 to 3200°F)
  S: 260 to 1760°C (500 to 3200°F)
  B: 870 to 1820°C (1598 to 3308°F)
  C: 0 to 2315°C (32 to 4200°F)
  N: -100 to 1260°C (-148 to 2300°F)
Accuracy: @ 25°C
  Types J and K: ±0.5% rdg or ±1.0°C (1.8°F), whichever is greater
  Types T, E, and N: ±0.5% rdg or ±2.0°C (3.6°F), whichever is greater
  Types R, S, B and C: ±0.5% FS
Resolution: 1°C/1°F
Sensor Connection: Screw terminals

MODEL UWXL-24-RTD
Input: Pt100 RTD; 0.00385 or 0.00392 curve, software selectable
Measurement Range:
  Pt100, 0.00385: -200 to 850°C (-328 to 1562°F)
  Pt100, 0.00392: -100 to 457°C (-148 to 854°F)
Accuracy: ±0.5°C (1.0°F)
Resolution: 1°C/1°F
Sensor Connection: Screw terminals

MODEL UWXL-24-IR-1
Temperature Range: -18 to 538°C (0 to 1000°F)
Accuracy: ±2% rdg or 2.2°C (4°F), whichever is greater; @ 22°C (72°F) ambient temperature and emissivity =0.95
Optical Field of View: 6:1 (distance/spot size)
Sensor Head Cable Extension: Up to 15 m (50 ft) total
Repeatability: ±1% rdg
Spectral Response: 5 to 14 microns
Response Time: 100 ms (0 to 63% of final value)
Emissivity: 0.1 to 1.00, adjustable Operating Ambient:
  Sensor Head: 0 to 70°C (32 to158°F)
  Sensor Head (-HT Model): 0 to 85°C (32 to 185°F)
   Sensor head with OS100-WC (Water Cooling Jacket): 0 to 200°C (32 to 392°F)
  Relative Humidity: Less than 95% RH, non-condensing
OS100-WC Water Flow Rate: 0.25 GPM, room temperature
Thermal Shock: About 30 min for 25°C (77°F) abrupt ambient temperature change
Warm-Up Period: 3 minutes
OS100-AP Air Flow Rate: 1 CFM (0.5 L/s) (1 x 2.5in)

OS100-LA LASER SIGHT ACCESSORY:
Wavelength (Color): 630 to 670 nm (red) Operating Distance (Laser Dot): Up to 9.1 m (30 ft)
Max Output Optical Power: Less than 1 mW @ -6°C (22°F) ambient temperature
European Classification: Class 2, EN60825-1/11.2001
Max Operating Current: 45 mA @ 3 Vdc
FDA Classification: Complies with 21 CFR 1040.10, Class II laser product
Beam Diameter: 5 mm (0.20 in)
Beam Divergence: <2 mrad
Operating Ambient: 0 to 50°C (32 to 122°F); <95% RH, non-condensing
Power Switch: On/off slide switch on the battery pack
Power Indicator: Red LED
Power: Battery pack, 3 Vdc (consists of two 1.5 Vdc “AA” lithium batteries, included)

MODEL UWXL-24-PC
Input: 0 to 1 Vdc, 0 to 5 Vdc, 0 to 10 Vdc, 0 to 20 A, 4 to 20 mA
Accuracy: ±0.1% FS @ 25°C
Resolution: 12 to 15 bit
Connection: M12

MODEL UWXL-24-RH Temperature
  Range: -17 to 49°C (2 to 120°F)
  Accuracy: ±1°C (±1.8°F) @ 25°C
  Resolution: 1°C/1°F
Relative Humidity
  Range: 2 to 98% RH
  Accuracy: ±2.5% RH from 20 to 80% RH; ±3.5% RH <20 and >80% RH @ 25°C (76°F)
  Resolution: 1%

RH MODEL UWXL-24-PH
pH Input:
  Range: 0 to 14 pH
  Accuracy: ±0.1 pH @ 25°C
  Resolution: 0.01 pH
  Response Time: 2 s
  Input Connection: BNC
  Temperature Compensation: Automatic, 0 to 100°C (32 to 212°F)
RTD Temperature Input:
  Type: Pt100 Ω RTD, 0.00385 curve
  Range: 0 to 100°C (32 to 212°F)
  Accuracy: ±1°C (1.8°F)
  Resolution: 0.1°
  Input Connection: Screw terminals
注文する (部品番号ビルダーより掲載以外の製品もご選択いただけます)(注文数を入力の上、"カートに追加"をクリックしてください)

他のお客様はこのような商品も購入しています。: このアイコンをクリックすると、このモデルを購入した他のお客様の購入商品リストが表示されます.

部品番号/Desc.
注文数
商品説明
Wireless Transmitters
  
UWXL-24-TC
お問い合せ下さい   
納期: 
 
 
Wireless thermocouple transmitter
  
UWXL-24-RTD
¥120,472 (税込)
(税抜価格 ¥109,520)
納期: 2 週間
 
Wireless RTD (Pt100) transmitter
  
UWXL-24-PC
お問い合せ下さい   
納期: 
 
 
Wireless process voltage and current input transmitter
  
UWXL-24-IR-1
お問い合せ下さい   
納期: 
 
 
Wireless infrared temperature transmitter
  
UWXL-24-RH-RP1
お問い合せ下さい   
納期: 
 
 
Wireless humidity/temperature transmitter with remote probe
  
UWXL-24-PH
¥120,472 (税込)
(税抜価格 ¥109,520)
納期: 5 週間
 
Wireless pH/temperature transmitter
Wireless Receivers
Click to expand/minimize a list of what others bought with theUWTC-REC1
UWTC-REC1
¥72,178 (税込)
(税抜価格 ¥65,616)
納期: 4 週間
 
48-channel wireless USB powered receiver (no analog output or alarms)
  
UWTC-REC2-V1
¥91,597 (税込)
(税抜価格 ¥83,270)
納期: 8 週間
 
48-channel wireless receiver with 1-channel 0 to 5 Vdc analog output and alarms
Click to expand/minimize a list of what others bought with theUWTC-REC2-D-V1
UWTC-REC2-D-V1
お問い合せ下さい   
納期: 
 
 
48-channel wireless receiver with display and 1-channel 0 to 5 Vdc analog output and alarms
  
UWTC-REC2-V2
お問い合せ下さい   
納期: 
 
 
48-channel wireless receiver with 1-channel 0 to 10 Vdc analog output and alarms
Click to expand/minimize a list of what others bought with theUWTC-REC2-D-V2
UWTC-REC2-D-V2
¥110,935 (税込)
(税抜価格 ¥100,850)
納期: 8 週間
 
48-channel wireless receiver with display and 1-channel 0 to 10 Vdc analog output and alarms
Click to expand/minimize a list of what others bought with theUWTC-REC2-MA
UWTC-REC2-MA
¥99,847 (税込)
(税抜価格 ¥90,770)
納期: 8 週間
 
48-channel wireless receiver with 1-channel 4 to 20 mA analog output and alarms
Click to expand/minimize a list of what others bought with theUWTC-REC2-D-MA
UWTC-REC2-D-MA
¥110,935 (税込)
(税抜価格 ¥100,850)
納期: 8 週間
 
48-channel wireless receiver with display and 1-channel 4 to 20 mA analog output and alarms
Click to expand/minimize a list of what others bought with theUWTC-REC3
UWTC-REC3
お問い合せ下さい   
納期: 
 
 
32-channel receiver/host with ethernet
  
DPi1701-USB-ARW
お問い合せ下さい   
納期: 
 
 
Graphical panel Display and Logging Wireless Receiver
Wireless Receivers, DIN Rail Mount
  
UWTC-REC4-V1
¥104,687 (税込)
(税抜価格 ¥95,170)
納期: 8 週間
 
48-channel DIN rail mount wireless receiver with 1-channel 0 to 5 Vdc analog output and alarms
  
UWTC-REC4-V2
¥114,109 (税込)
(税抜価格 ¥103,735)
納期: 4 週間
 
48-channel DIN rail mount wireless receiver with 1-channel 0 to 10 Vdc analog output and alarms
Click to expand/minimize a list of what others bought with theUWTC-REC4-MA
UWTC-REC4-MA
¥114,109 (税込)
(税抜価格 ¥103,735)
納期: 4 週間
 
48-channel DIN rail mount wireless receiver with 1-channel 4 to 20 mA analog output and alarms
Accessories
  
UWXL-RAK
¥11,105 (税込)
(税抜価格 ¥10,095)
納期: 2 週間
 
Remote antenna kit
Click to expand/minimize a list of what others bought with theUWTC-BATT-C
UWTC-BATT-C
¥15,219 (税込)
(税抜価格 ¥13,835)
納期: 4 週間
 
Replacement battery assembly
  
UWTC-CB12
お問い合せ下さい   
納期: 
 
 
12-channel USB control box with 12 form “C” relays
UWXL-24-PH Accessories
Click to expand/minimize a list of what others bought with thePHE-1311
PHE-1311
¥20,813 (税込)
(税抜価格 ¥18,921)
納期: 2 週間
 
Gel-filled pH electrode, general purpose
  
PRTF-10-2-1000-1/8-6-E-TA3F
お問い合せ下さい   
納期: 
 
 
Pt1000 RTD probe, 1/8 in dia, 6 in L, wire, 40 ft PFA insulated cable with connector
UWXL-IR-1 Accessories
注: Each unit comes complete with measurement/charting/data logging software, USB cable and operator's manual. UWTC-REC2 units also include dc power adaptor.

Note: Because of transmission frequency regulations, these products may only be used in the United States and Canada.

Ordering Example: (1) UWXL-24-TC Wireless thermocouple transmitter, ¥109,520   plus (1) UWXL-REC1 48-channel wireless receiver, ¥116,290, ¥109,520 + 116,290 = ¥225,810

製品マニュアル:

ダウンロード Manual For Long Distance Industrial Wireless pH Transmitters
ダウンロード Manual For Long Distance Industrial Wireless Infrared Temperature Transmitters
ダウンロード Manual For Industrial Wireless Transmitters - Long Distance - Process Input
ダウンロード Manual For Industrial Wireless Thermocouple/RTD Transmitters
ダウンロード Manual For Industrial Wireless Humidity/Temperature Transmitter with Remote Probe
We noticed you are from the US. Visit your local site for regional offers and live support.