Tubular Heater Round Cross-Section, 30 Watts/Square Inch, 450 - 4750 Watts, Incoloy Sheath Diameters(inches): 0.475, 0.430, 0.375, 0.315, 0.260, 0.246  - Discontinued

TRI Style

Tubular Heater | TRI Style

Tubular Heater

商品説明

The TRI series has been discontinued. Please contact our Temperature Engineering department for a viable replacement.

.475" (12.07 mm) DIAMETER
ROUND CROSS-SECTION




Watts Volts W/In2 Dimensions In. (cm) INCOLOY Sheath
Model No.
Weight
Lb (kg)
Sheath A Heated B
4501203016 (41)9 1/8 (23)TRI-1645/120V0.5 (0.2)
5401203018 (46)11 1/8 (28)TRI-1845/120V0.5 (0.2)
6351203020 (51)13 1/8 (33)TRI-2045/120V0.5 (0.2)
7501203023 (58)16 1/8 (41)TRI-2345/120V0.5 (0.2)
7502403023 (58)16 1/8 (41)TRI-2345/240V0.5 (0.2)
8252403025 (64)18 1/8 (46)TRI-2545/240V0.7
9002403027 (69)20 1/8 (51)TRI-2745/240V0.9
10001203028 (71)21 1/8 (54)TRI-2845/120V1
10002403028 (71)21 1/8 (54)TRI-2845/240V1
11002403030 (76)23 1/8 (59)TRI-3045/240V1
12002403032 (81)25 1/8 (64)TRI-3245/240V1.1
12752403034 (86)27 1/8 (69)TRI-3445/240V1.1
13502403036 (91)29 1/8 (74)TRI-3645/240V1.2
15001203040 (102)33 1/8 (84)TRI-4045/120V1.3
15002403040 (102)33 1/8 (84)TRI-4045/240V1.3
17252403044 (112)37 1/8 (94)TRI-4445/240V1.4
18002403046 (117)39 1/8 (99)TRI-4645/240V1.6
19502403050 (127)43 1/8 (110)TRI-5045/240V1.8
200024030541/4 (138)47 3/8 (120)TRI-5445/240V1.8
22502403058 (147)51 (130)TRI-5845/240V1.8
25001203060 (152)53 (135)TRI-6045/120V1.8
25002403060 (152)53 (135)TRI-6045/240V1.8
27502403066 (168)59 (150)TRI-6645/240V1.8
30002403070 (178)63 (160)TRI-7045/240V1.8
31252403074 (188)67 (170)TRI-7445/240V1.8
32502403078 (198)71 (180)TRI-7845/240V1.8
35002403085 (216)78 (198)TRI-8545/240V2.3
400024030100 (254)93 (236)TRI-10045/240V3.3
450024030108 (274)101 (257)TRI-10845/240V3.3
475024030112 (284)105 (267)TRI-11245/240V3.3



.430"(10.92 mm) DIAMETER
ROUND CROSS-SECTION




Watts Volts W/In2 Dimensions In. (cm) INCOLOY Sheath
Model No.
Weight
Lb (kg)
Sheath A Heated B
4001203016 (41)9 1/8 (23)TRI-1644/120V0.5
5751203020 (51)13 1/8 (33)TRI-2044/120V0.5
9002403028 (71)21 1/8 (56)TRI-2844/240V1
11002403032 (81)25 1/8 (64)TRI-3244/240V1.1
13002403036 (91)29 1/8 (74)TRI-3644/240V1.2
14002403040 (102)33 1/8 (84)TRI-4044/240V1.2
20002403054 (137)47 1/8 (120)TRI-5444/240V1.7
23002403060 (152)53 (135)TRI-6044/240V1.7
25002403066 (168)59 (150)TRI-6644/240V1.7
27002403070 (178)63 (160)TRI-7044/240V1.7
31002403078 (198)71 (180)TRI-7844/240V1.7
34002403085 (216)78 (198)TRI-8544/240V2.2
400024030100 (254)93 (236)TRI-10044/240V3.2
430024030108 (274)101 (257)TRI-10844/240V3.2
450024030112 (284)105 (267)TRI-11244/240V3.2



.375" (9.53 mm) DIAMETER
ROUND CROSS-SECTION




Watts Volts W/In2 Dimensions In. (cm) INCOLOY Sheath
Model No.
Weight
Lb (kg)
Sheath A Heated B
3501203016 (41)9 1/4 (23)TRI-1643/120V0.4
5001203020 (51)13 1/4 (34)TRI-2043/120V0.4
8001203028 (71)21 1/4 (54)TRI-2843/120V0.8
8002403028 (71)21 1/4 (54)TRI-2843/240V0.8
9501203032 (81)25 1/4 (64)TRI-3243/120V0.8
9502403032 (81)25 1/4 (64)TRI-3243/240V0.8
11002403036 (91)29 1/4 (74)TRI-3643/240V0.8
13001203042 (107)35 1/4 (90)TRI-4243/120V1
13002403042 (107)35 1/4 (90)TRI-4243/240V1
15002403048 (122)41 1/4 (105)TRI-4843/240V1.1
18001203054 (137)47 1/4 (120)TRI-5443/120V1.3
18002403054 (137)47 1/4 (120)TRI-5443/240V1.3
21002403062 (157)55 1/4 (140)TRI-6243/240V1.3
24002403070 (178)63 1/4 (161)TRI-7043/240V1.3
30002403086 (218)79 1/4 (201)TRI-8643/240V1.8
360024030102 (259)95 1/4 (242)TRI-10243/240V2
400024030112 (284)105 1/4(268)TRI-11243/240V2.5



.315" (8 mm) DIAMETER
ROUND CROSS-SECTION




Watts Volts W/In2 Dimensions In. (cm) INCOLOY Sheath
Model No.
Weight
Lb (kg)
Sheath A Heated B
2751203016 (41)9 1/4 (23)TRI-1648/120V0.4
3501203018 (46)11 1/4 (29)TRI-1848/120V0.4
4001203020 (51)13 1/4 (34)TRI-2048/120V0.4
5001203022 (56)15 1/4 (39)TRI-2248/120V0.5
6501203025 (64)18 1/4 (46)TRI-2548/120V0.6
6502403025 (64)18 1/4 (46)TRI-2548/240V0.6
7001203027 (69)20 1/4 (51)TRI-2748/120V0.7
7002403027 (69)20 1/4 (51)TRI-2748/240V0.7
6251203028 (71)21 1/4 (54)TRI-2848/120V0.8
6252403028 (71)21 1/4 (54)TRI-2848/240V0.8
8001203030 (76)23 1/4 (59)TRI-3048/120V0.8
8002403030 (76)23 1/4 (59)TRI-3048/240V0.8
7501203032 (81)25 1/4 (64)TRI-3248/120V0.8
7502403032 (81)25 1/4 (64)TRI-3248/240V0.8
9001203034 (86)27 1/4 (69)TRI-3448/120V0.8
9002403034 (86)27 1/4 (69)TRI-3448/240V0.8
8501203036 (91)29 1/4 (74)TRI-3648/120V0.8
8502403036 (91)29 1/4 (74)TRI-3648/240V0.8
10501203038 (97)31 1/4 (79)TRI-3848/120V0.9
10502403038 (97)31 1/4 (79)TRI-3848/240V0.9
9751203040 (102)33 1/4 (84)TRI-4048/120V1
9752403040 (102)33 1/4 (84)TRI-4048/240V1
12001203042 (107)35 1/4 (90)TRI-4248/120V1
12002403042 (107)35 1/4 (90)TRI-4248/240V1
12501203044 (112)37 1/4 (95)TRI-4448/120V1
12502403044 (112)37 1/4 (95)TRI-4448/240V1
11501203046 (117)39 1/4 (100)TRI-4648/120V1
11502403046 (117)39 1/4 (100)TRI-4648/240V1
11504803046 (117)39 1/4 (100)TRI-4648/4801
13501203048 (122)41 1/4 (105)TRI-4848/120V1.1
13502403048 (122)41 1/4 (105)TRI-4848/240V1.1
14501203050 (127)43 1/4 (110)TRI-5048/120V1.2
14502403050 (127)43 1/4 (110)TRI-5048/240V1.2
13251203052 (132)45 1/4 (115)TRI-5248/120V1.3
13252403052 (132)45 1/4 (115)TRI-5248/240V1.3
13254803052 (132)45 1/4 (115)TRI-5248/4801.3
15501203054 (137)47 1/4 (120)TRI-5448/120V1.3
15502403054 (137)47 1/4 (120)TRI-5448/240V1.3
15001203058 (147)51 1/4 (130)TRI-5848/120V1.3
15002403058 (147)51 1/4 (130)TRI-5848/240V1.3
15004803058 (147)51 1/4 (130)TRI-5848/4801.3
18501203062 (157)55 1/4 (140)TRI-6248/120V1.3
18502403062 (157)55 1/4 (140)TRI-6248/240V1.3
16751203064 (163)57 1/4 (145)TRI-6448/120V1.3
16752403064 (163)57 1/4 (145)TRI-6448/240V1.3
16754803064 (163)57 1/4 (145)TRI-6448/4801.3
19501203066 (168)59 1/4 (150)TRI-6648/120V1.3
19502403066 (168)59 1/4 (150)TRI-6648/240V1.3
18501203070 (178)63 1/4 (161)TRI-7048/120V1.3
18502403070 (178)63 1/4 (161)TRI-7048/240V1.3
18504803070 (178)63 1/4 (161)TRI-7048/4801.3
22502403074 (188)67 1/4 (163)TRI-7448/240V1.5
20251203076 (193)69 1/4 (176)TRI-7648/120V1.5
20252403076 (193)69 1/4 (176)TRI-7648/240V1.5
20254803076 (193)69 1/4 (176)TRI-7648/4801.5
23502403078 (198)71 1/4 (181)TRI-7848/240V1.5
22001203082 (208)75 1/4 (191)TRI-8248/120V1.8
22002403082 (208)75 1/4 (191)TRI-8248/240V1.8
22004803082 (208)75 1/4 (191)TRI-8248/4801.8
26002403086 (218)79 1/4 (201)TRI-8648/240V1.8
23752403088(224)81 1/4 (206)TRI-8848/240V1.8
23754803088(224)81 1/4 (206)TRI-8848/4801.8
27502403090(229)83 1/4 (211)TRI-9048/240V1.8
25502403094(239)87 1/4 (222)TRI-9448/240V1.8
25504803094 (239)87 1/4 (222)TRI-9448/4801.8
30002403098 (249)91 1/4 (232)TRI-9848/240V2
270024030100(254)93 1/4 (237)TRI-10048/240V2
270048030100 (254)93 1/4 (237)TRI-10048/4802
315024030102 (259)95 1/4 (242)TRI-10248/240V2
287524030106 (269)99 1/4 (252)TRI-10648/240V2.3
287548030106 (269)99 1/4 (252)TRI-10648/4802.3
305024030112 (284)105 1/4 (267)TRI-11248/240V2.5
305048030112 (284)105 1/4 (267)TRI-11248/4802.5



.260" (6.6 mm) DIAMETER
ROUND CROSS-SECTION




Watts Volts W/In2 Dimensions In. (cm) INCOLOY Sheath
Model No.
Weight
Lb (kg)
Sheath A Heated B
1751203012 (30)7 1/2 (19)TRI-1216/120V0.2
2701203016 (41)11 1/2 (29)TRI-1616/120V0.3
3601203020 (51)15 1/2 (39)TRI-2016/120V0.3
3602403020 (51)15 1/2 (39)TRI-2016/240V0.3
4501203024 (61)19 1/2 (50)TRI-2416/120V0.3
4502403024 (61)19 1/2 (50)TRI-2416/240V0.3
5501203028 (71)23 1/2 (60)TRI-2816/120V0.5
5502403028 (71)23 1/2 (60)TRI-2816/240V0.5
6501203032 (81)27 1/2 (70)TRI-3216/120V0.6
6502403032 (81)27 1/2 (70)TRI-3216/240V0.6
7251203036 (91)31 1/2 (80)TRI-3616/120V0.6
7252403036 (91)31 1/2 (80)TRI-3616/240V0.6
8251203040(102)35 1/2 (90)TRI-4016/120V0.7
8252403040(102)35 1/2 (90)TRI-4016/240V0.7
9751203046(117)41 1/2 (105)TRI-4616/120V0.7
9752403046(117)41 1/2 (105)TRI-4616/240V0.7
11001203052(132)47 1/2 (121)TRI-5216/120V0.9
11002403052(132)47 1/2 (121)TRI-5216/240V0.9
12501203058(147)53 1/2 (136)TRI-5816/120V0.9
12502403058(147)53 1/2 (136)TRI-5816/240V0.9
14001203064(163)59 1/2 (151)TRI-6416/120V0.9
14002403064(163)59 1/2 (151)TRI-6416/240V0.9
15251203070(178)65 1/2 (166)TRI-7016/120V0.9
15252403070(178)65 1/2 (166)TRI-7016/240V0.9
16501203076(193)71 1/2 (182)TRI-7616/120V0.9
16502403076(193)71 1/2 (182)TRI-7616/240V0.9
18001203082(208)77 1/2 (197)TRI-8216/120V1.3
18002403082(208)77 1/2 (197)TRI-8216/240V1.3
19501203088(224)83 1/2 (212)TRI-8816/120V1.3
19502403088(224)83 1/2 (212)TRI-8816/240V1.3
21002403094 (239)89 1/2 (227)TRI-9416/240V1.3
220024030100 (225)95 1/2 (243)TRI-10016/240V1.7
235024030106(269)101 1/2 (258)TRI-10616/240V1.7
250024030112(284)107 1/2 (273)TRI-11216/240V1.7



.246"(6.25 mm) DIAMETER
ROUND CROSS-SECTION




Watts Volts W/In2 Dimensions In. (cm) INCOLOY Sheath
Model No.
Weight
Lb (kg)
Sheath A Heated B
1651203012 (30)7 1/2 (19)TRI-1212/120V0.2
2551203016 (41)11 1/2 (29)TRI-1612/120V0.3
3401203020 (51)15 1/2 (39)TRI-2012/120V0.3
3402403020 (51)15 1/2 (39)TRI-2012/240V0.3
4301203024 (61)19 1/2 (50)TRI-2412/120V0.3
4302403024 (61)19 1/2 (50)TRI-2412/240V0.3
5151203028 (71)23 1/2 (60)TRI-2812/120V0.5
5152403028 (71)23 1/2 (60)TRI-2812/240V0.5
6051203032 (81)27 1/2 (70)TRI-3212/120V0.5
6052403032 (81)27 1/2 (70)TRI-3212/240V0.5
6901203036 (91)31 1/2 (80)TRI-3612/120V0.5
6902403036 (91)31 1/2 (80)TRI-3612/240V0.5
7801203040(102)35 1/2 (90)TRI-4012/120V0.7
7802403040(102)35 1/2 (90)TRI-4012/240V0.7
9101203046(117)41 1/2 (105)TRI-4612/120V0.7
9102403046(117)41 1/2 (105)TRI-4612/240V0.7
10451203052(132)47 1/2 (121)TRI-5212/120V0.9
10452403052(132)47 1/2 (121)TRI-5212/240V0.9
11751203058(147)53 1/2 (136)TRI-5812/120V0.9
11752403058(147)53 1/2 (136)TRI-5812/240V0.9
13101203064(163)59 1/2(151)TRI-6412/120V0.9
13102403064(163)59 1/2(151)TRI-6412/240V0.9
14401203070(178)65 1/2 (166)TRI-7012/120V0.9
14402403070(178)65 1/2 (166)TRI-7012/240V0.9
15701203076(193)71 1/2 (182)TRI-7612/120V0.9
15702403076(193)71 1/2 (182)TRI-7612/240V0.9
17001203082(208)77 1/2 (197)TRI-8212/120V1.2
17002403082(208)77 1/2 (197)TRI-8212/240V1.2
18351203088(224)83 1/2 (212)TRI-8812/120V1.2
18352403088(224)83 1/2 (212)TRI-8812/240V1.2
19652403094 (239)89 1/2 (227)TRI-9412/240V1.2
210024030100 (225)95 1/2 (243)TRI-10012/240V1.7
223024030106(269)101 1/2 (258)TRI-10612/240V1.7
236524030112(284)107 1/2 (273)TRI-11212/240V1.7
注文する (部品番号ビルダーより掲載以外の製品もご選択いただけます)(注文数を入力の上、"カートに追加"をクリックしてください)
部品番号/Desc.
注文数
商品説明
Example part numbers are shown below. For additional configurations see the Part Number Builder below this table.
Quick Ship
TRI-2345/120V
お問い合せ下さい   
納期: 
 
 
Heater, 750 W 120V
Quick Ship
TRI-10845/240V
お問い合せ下さい   
納期: 
 
 
Heater, 4500 W, 240 V
Quick Ship
TRI-11245/240V
お問い合せ下さい   
納期: 
 
 
Heater, 4750 W, 240 V
Quick Ship
TRI-1648/120V
お問い合せ下さい   
納期: 
 
 
Heater, 275 W, 120 V
Quick Ship
TRI-2012/240V
お問い合せ下さい   
納期: 
 
 
Heater, 340 W, 240 V
Quick Ship
TRI-11212/240V
お問い合せ下さい   
納期: 
 
 
TUBULAR ELE HTR
Quick Ship
TRI-2545/240V
お問い合せ下さい   
納期: 
 
 
TUBULAR ELE HTR
Quick Ship
TRI-2412/240V
お問い合せ下さい   
納期: 
 
 
TUBULAR ELE HTR
Quick Ship
TRI-2412/240V
お問い合せ下さい   
納期: 
 
 
TUBULAR ELE HTR
Quick Ship
TRI-2812/240V
¥14,940
納期: 2 週間
 
TUBULAR ELE HTR
Quick Ship
TRI-3216/120V
お問い合せ下さい   
納期: 
 
 
TUBULAR ELE HTR
Quick Ship
TRI-3616/240V
お問い合せ下さい   
納期: 
 
 
TUBULAR ELE HTR
Quick Ship
TRI-3848/120V
お問い合せ下さい   
納期: 
 
 
TUBULAR ELE HTR
Quick Ship
TRI-4016/120V
お問い合せ下さい   
納期: 
 
 
TUBULAR ELE HTR
Quick Ship
TRI-4016/240V
お問い合せ下さい   
納期: 
 
 
TUBULAR ELE HTR
Quick Ship
TRI-4445/240V
お問い合せ下さい   
納期: 
 
 
TUBULAR ELE HTR
Quick Ship
TRI-4612/120V
お問い合せ下さい   
納期: 
 
 
TUBULAR ELE HTR
Quick Ship
TRI-4648/480V
お問い合せ下さい   
納期: 
 
 
TUBULAR ELE HTR
Quick Ship
TRI-4445/240V
お問い合せ下さい   
納期: 
 
 
TUBULAR ELE HTR
Quick Ship
TRI-4612/120V
お問い合せ下さい   
納期: 
 
 
TUBULAR ELE HTR
Quick Ship
TRI-4648/480V
お問い合せ下さい   
納期: 
 
 
TUBULAR ELE HTR
Quick Ship
TRI-4848/240V
お問い合せ下さい   
納期: 
 
 
TUBULAR ELE HTR
Quick Ship
TRI-7048/480V
お問い合せ下さい   
納期: 
 
 
TUBULAR ELE HTR
Quick Ship
TRI-5216/120V
お問い合せ下さい   
納期: 
 
 
TUBULAR ELE HTR
Quick Ship
TRI-8212/120V
お問い合せ下さい   
納期: 
 
 
TUBULAR ELE HTR
Quick Ship
TRI-10845/240V
お問い合せ下さい   
納期: 
 
 
TUBULAR ELE HTR
Quick Ship
TRI-11245/240V
お問い合せ下さい   
納期: 
 
 
TUBULAR ELE HTR

クイックオーダー

部品番号
注文数
部品番号
注文数


このサイトの金額はすべて日本円(税抜)で表示しています
Did you know Omega has an office in the United States with local pricing and live engineers to support you in your time zone?