Solid-State Relays for Intrinsic Safety

SBG22445A,SBG25872A,SBG25873A,SBG41705A

Solid-State Relays for Intrinsic Safety | SBG22445A,SBG25872A,SBG25873A,SBG41705A

Solid-State Relays for Intrinsic Safety

¥47,275 SBG22445A

RoHS
  • Rapid, Arc-Free Response for Positive, Non-Mechanical Operation
  • Solid-State Reliability to Insure Consistent Performance
  • Low-Power Switching where a Few Milliamps of Current Control High-Power Loads
  • Completely Encapsulated Construction Impervious to Dust, Moisture or Foreign Material
  • Standardized, Modular Housings for Easier Installation
  • Exceptionally Long, Trouble-Free Service Life
  • Latching and Non-Latching Models
レベルスイッチ / レベルセンサ - 関連する商品を探す
(見つからない場合はカスタマーサービスにご連絡ください)

商品説明

Solid-State Relay:
Less than 100 microamps at 14 Vdc actuates the unit to control ac loads to 5 amps at 120 Vac. Resistive (up to 400,000 ohms) or short-circuiting sensors operate the unit. 115 Vac and 230 Vac models.

Latching Solid-State Relay:
Momentary actuation, “start-stop” or differential control switching for resistive loads to 0.3 amps, 115 Vac model. OMEGA™ solid-state relays for intrinsic safety allow non-voltage producing switches mounted in the hazardous area to safely control higher power ac loads in the nonhazardous area. Typical applications include flow, level and pressure switches which may be inputs to an alarm or control system.



Model No. Description Line & Load
Voltage
Range
Load
Current
Max
Turn-On
Sensitivity
(Typical)
Turn-Off
Sensitivity
(Typical)
Voltage
Loss
Operating
Temperature
Range
Output
Leakage
Current Max.
Switching
Operation
SBG22445A
SSR for
Intrinsic
Safety

95 to
135 Vac
5A<=400 K Ω1 meg. Ω2 Vac0° to +120°F
6 mA @
120 Vac
SPST N.O.
SBG25872A100 to
135 Vac
6 mA @
120 Vac
SPST N.C.
SBG25873A200 to
250 Vac
12 mA @
250 Vac
SPST N.O.
SBG41705ALatching SSR
for Intrinsic
Safety
105 to
125 Vac
0.3 A
Steady
State
<=25 K Ω1 meg. Ω2 Vac+32° to +°120°F3 mA @
120 Vac
SPST N.O.
Note 1: For typical wiring diagrams, see next page.
Note 2: All ac voltage and current specifications are RMS values unless otherwise stated.
Note 3: Housing material is Polysulfone.
注文する (部品番号ビルダーより掲載以外の製品もご選択いただけます)(注文数を入力の上、"カートに追加"をクリックしてください)

他のお客様はこのような商品も購入しています。: このアイコンをクリックすると、このモデルを購入した他のお客様の購入商品リストが表示されます.

部品番号/Desc.
注文数
RoHS
商品説明
Quick Ship
Click to expand/minimize a list of what others bought with theLVC551
LVC551
お問い合せ下さい   
納期: 
 
RoHS compliant
8 Amps resistive at up to 120 Vac; Field Selectable high/low, latching/non latching, pump up/pump down
Quick Ship
  
LVC552
¥55,800
納期: 10 週間
RoHS compliant
8 Amps resistive at up to 120 Vac; Field Selectable high/low, latching/non latching, pump up/pump down
Quick Ship
  
SBG22445A
¥47,275
納期: 6 週間
RoHS compliancy undetermined
SSR for Intrinsic Safety 95 to 135 Vac
Quick Ship
  
SBG25872A
¥47,275
納期: 2 週間
RoHS compliancy undetermined
SSR for Intrinsic Safety 95 to 135 Vac
Quick Ship
  
SBG25873A
¥47,275
納期: 2 週間
RoHS compliancy undetermined
SSR for Intrinsic Safety 200 to 250Vac
Quick Ship
  
SBG41705A
¥64,890
納期: 2 週間
RoHS compliancy undetermined
Latching SSR for Intrinsic Safety 105 to 125 Vac
このサイトの金額はすべて日本円(税抜)で表示しています
注: Comes complete with operator's manual.


Ordering Example: (1) SBG41705A Latching SSR for Intrinsic Safety, ¥64,890

製品マニュアル:

ダウンロード SBG111950 - INTRINSIC SAFETY RELAY
ダウンロード SBG54806 - INTRINSIC SAFETY RELAY
ダウンロード SBG54803 - INTRINSIC SAFETY RELAY
ダウンロード SBG22445 - INTRINSIC SAFETY RELAY
ダウンロード LVC551 - Intrinsic Safe Relay
ダウンロード SSRL Series - Solid State Relays