カート  |  お問い合わせ  | 
フリーダイヤル 0120-971-357
海外からのお問合せ+81-3-5244-4675

Miniature Plastic Case Transducer with 1 to 6 Volt Output Temperature Compensated - PX184 Discontinued

PX184 & PX185

Miniature Plastic Case Transducer with 1 to 6 Volt Output Temperature Compensated | PX184 & PX185

スクロールダウンし、全ラインアップをご覧ください

1 year warranty
  • Differential and Vacuum Models
  • Linear Signal With Pressure
  • Amplified Fully Signal Conditioned Output

商品説明

The PX184, PX185 and PX186 series are being discontinued. Please see the PX140 Series as possible alternatives or contact our Pressure Engineering department.

SPECIFICATIONS

Excitation: 8 Vdc (7 to 16 maximum)

Output: 1 to 6 Vdc

Supply Current: 6 mA maximum

Linearity: P2 > P1 = ±2%

Repeatability & Hysteresis:

±0.15% FS

Zero: 1V ±0.05V

Span: 5V ±0.05V

Overpressure: 5 psi = 20 psi

15 psi = 45 psi

30 psi = 60 psi

Operating Temperature:

-40 to +185°F (-40 to 85°C)

Compensated Temperature:

32 to 122°F (0 to 50°C)

Port: 0.20 in tube fitting

Mounting: Printed circuit board

Response Time: 1 ms

Mating Connector: CX136-4 (not

included) See page C-3

このサイトの金額はすべて日本円(税抜)で表示しています
注: Requires PST-8 external power supply.
Ordering Example: (1) PX185-030D5V has a 0 to 30 psi differential pressure range, ¥21,060