The high temperature insertion type electrode is designed for periodic exposure to steam sterilization or continuous high temperature. This pH electrode is housed in a durable thermoplastic (PAS) body and is rated for temperatures up to 135°C. The use of the double Porous PTFE liquid junctions with matched viscosity electrolytes provides a reference cell which permits extended periods of pH measurements in the presence of sulfides or other silver complexing agents. This electrode also incorporates pressure compensating devices to protect the electrode from extreme temperature induced pressure deviations. Ten foot cable length and BNC connector are standard.

Application
• High Temperature Environment
• Continuous Processing Applications
• Harsh Conditions
• Steam Sterilization

Specifications
pH Range: 0 to 14 pH
Temperature Range:
-5 to +135°C (23 to 275°F)
Pressure Range: 500 psig @ 25°C
Accuracy: ±0.1% over full range
Impedance: 125 Mohm (standard version)
Reference Cell: Double Junction, KCl/AgCl, KNO3
Reference Junction: Porous PTFE
Wetted Materials: PTFE, Glass membrane, polymer outer body, EPR “O” Rings
Response Time: 95% of reading in 10 seconds
Drift: Less than 2 mV per week
注文する (部品番号ビルダーより掲載以外の製品もご選択いただけます)(注文数を入力の上、"カートに追加"をクリックしてください)

他のお客様はこのような商品も購入しています。: このアイコンをクリックすると、このモデルを購入した他のお客様の購入商品リストが表示されます.

部品番号/Desc.
注文数
RoHS
商品説明
High Temperature Insertion Style pH Electrode
Quick Ship
  
PHE-5431-10
¥32,865
納期: 2 週間
RoHS compliant
High temperature electrode with 3 m (10') of cable
Quick Ship
  
PHE-5431-10-PT100
¥42,780
納期: 2 週間
RoHS compliant
High temperature pH electrode with 3 m (10') of cable and 100Ω Platinum RTD
Quick Ship
  
PHE-5431-10-PT1K
¥42,780
納期: 10 週間
RoHS compliant
High temperature pH electrode with 3 m (10') of cable and 1000Ω Platinum RTD
Quick Ship
  
PHE-5431-10-PT100
¥42,780
納期: 2 週間
RoHS compliant
High temperature pH electrode with 4.6 m (15') of cable and 100Ω Platinum RTD
Quick Ship
  
PHE-5431-15-PT100
¥48,655
納期: 10 週間
RoHS compliant
High temperature pH electrode with 4.6 m (15') of cable and 100Ω Platinum RTD
Quick Ship
  
PHE-5431-17
¥40,025
納期: 10 週間
RoHS compliant
High temperature electrode with 5 m (170') of cable
Quick Ship
  
PHE-5431-20-PT100
¥51,410
納期: 10 週間
RoHS compliant
High temperature pH electrode with 6 m (20') of cable and 100Ω Platinum RTD
Quick Ship
  
PHE-5431-25
¥42,780
納期: 10 週間
RoHS compliant
High temperature electrode with 7.6 m (25') of cable
Quick Ship
  
PHE-5431-25-PT100
¥54,160
納期: 10 週間
RoHS compliant
High temperature pH electrode with 7.6 m (25') of cable and 100Ω Platinum RTD
Quick Ship
  
PHE-5431-35
¥46,820
納期: 10 週間
RoHS compliant
High temperature electrode with 10 m (35') of cable
Quick Ship
  
PHE-5431-50
¥54,160
納期: 10 週間
RoHS compliant
High temperature electrode with 15 m (50') of cable
Quick Ship
  
PHE-5431-50-PT100
¥64,260
納期: 10 週間
RoHS compliant
High temperature pH electrode with 15 m (50') of cable and 100Ω Platinum RTD
Oxidation Reduction Potential Electrodes
Quick Ship
  
ORE-5431-10
¥41,940
納期: 10 週間
RoHS compliant
High temperature insertion style with 3 m (10') of cable
Quick Ship
  
ORE-5431-25
¥53,100
納期: 10 週間
RoHS compliant
High temperature insertion style with 7.6 m (25') of cable
Accessories
Quick Ship
  
PHEH-51
¥25,740
納期: 10 週間
RoHS compliant
1/2 MNPT Installation Fitting
Quick Ship
Click to expand/minimize a list of what others bought with thePHA-10
PHA-10
¥2,333
納期: 2 週間
RoHS compliant
pH 10 buffer solutions 500 ml (1 pt)
Quick Ship
Click to expand/minimize a list of what others bought with thePHA-10-GAL
PHA-10-GAL
¥5,832
納期: 2 週間
RoHS compliant
pH 10 buffer solutions 4L (1 gal)
Quick Ship
Click to expand/minimize a list of what others bought with thePHA-4
PHA-4
¥2,250
納期: 2 週間
Not RoHS compliant
pH 4 buffer solutions 500 ml (1 pt)
Quick Ship
Click to expand/minimize a list of what others bought with thePHA-4-GAL
PHA-4-GAL
¥5,832
納期: 2 週間
RoHS compliant
pH 4 buffer solutions 4L (1 gal)
Quick Ship
Click to expand/minimize a list of what others bought with thePHA-7
PHA-7
¥2,333
納期: 2 週間
Not RoHS compliant
pH 7 buffer solutions 500 ml (1 pt)
Quick Ship
Click to expand/minimize a list of what others bought with thePHA-7-GAL
PHA-7-GAL
¥5,832
納期: 2 週間
RoHS compliant
pH 7 buffer solutions 4L (1 gal)
Quick Ship
Click to expand/minimize a list of what others bought with thePHA-DI
PHA-DI
¥2,520
納期: 2 週間
RoHS compliancy undetermined
De-ionized water 500 ml (1 pt)
Quick Ship
Click to expand/minimize a list of what others bought with thePHA-DI-GAL
PHA-DI-GAL
¥5,832
納期: 2 週間
RoHS compliancy undetermined
De-ionized water 4L (1 gal)
Quick Ship
  
PHAB-DI
¥5,715
納期: 2 週間
RoHS compliancy undetermined
20 single use foil packets of de-ionized water
Quick Ship
Click to expand/minimize a list of what others bought with thePHAB-PH
PHAB-PH
¥5,715
納期: 2 週間
RoHS compliancy undetermined
5 each single use foil packets of pH-4, pH-7, pH-10, and de-ionized water.
このサイトの金額はすべて日本円(税抜)で表示しています
注: Comes complete with electrode care instruction sheet.

For non-standard cable lengths, change the "-10" in the part number to the required length in feet, add $2 per foot to price (additional per foot cost applies to the entire length of cable.

For HF/Fluoride Resistant electrode, add suffix "-HF" to the model number, add $50 to price.

For 100O Platinum RTD Automatic Temperature Compensation (ATC), add suffix "-PT100" to the model number, add $50 to price.

For 1000O Platinum RTD Automatic Temperature Compensation (ATC), add suffix "-PT1K" to model number, add $50 to price.

For 3000O Balco, add suffix "-R3K" to model number, add $50 to price.

For European PG style connector, add suffix "-PG" to the model number, add $50 to price.

NOTE: PHEH-51 (1/2 MNPT) installation fitting is required for first time installation.