【販売終了】Handheld Pressure Calibrators with Interchangeable Pressure Modules

PCL-1B

Handheld Pressure Calibrators with Interchangeable Pressure Modules | PCL-1B

スクロールダウンし、全ラインアップをご覧ください

  • Plug-In Pressure Modules Provide Ranges from 0.25 Inches of Water to 7500 psi
  • Dual Display Shows Applied Pressure and Transducer Output Simultaneously
  • Very High Accuracy to 0.06% of Full Scale
  • Measures Pressure, Voltage, Current, Flow and Leak Rate

商品説明

PCL31は販売終了になりました。代替製品はPCL1200またはPCL1000シリーズになります。

The OMEGA ® PCL-1B handheld system introduces a new era in pressure calibration standards. This unique instrument measures pressure, flow, vacuum, leak, current, voltage and change-of-state for switch testing. A fully equipped PCL-1B system provides all calibration capabilities needed in virtually all pressure measurement and test applications. Each handheld system consists of a base unit and one or two plug-in pressure modules. An array of pressure modules is available to cover ranges from 0.25 inches H2O through 7500 psi. Modules can be interchanged quickly and easily without the use of tools. Select any combination of modules to meet your application needs. The PCL-1B pressure calibration and test system combines the capabilities of plug-in pressure modules with a wide selection of standard firmware features. This combination of firmware-related features and unlimited pressure sensor interchangeability make the PCL-1B one of the most powerful pressure calibration and test instruments available today.

SPECIFICATIONS

Available Accuracies (% of span compared to standard): ±0.07% of span (ranges below 1 in H2O) ±0.06% of span (from 0/1 through 0/200 in H2O)±0.05% of span (psi ranges only)
Repeatability: * ranges 0/5 psi and above ±0.02% of span (typical) ranges 0/2 psi and below ±0.05% of span
Sensitivity: * + 0.002% of span with damping 1 part in 50,000 (max)( * included in accuracy specifications)
Operating Temp. Range: 0 to 49°C (32 to 120°F)
Compensated Temp. Range: -7 to 49°C (20 to 120°F)
Reference Temperature: 21°C ±1.7°C (70° ±3°F)
Temperature Error: maximum of ±0.007% of span per over the compensated range for zero and span
Storage Limits: -20 to 70°C (-4 to 158°F)
Display: Alphanumeric LCD, 9.4 mm (0.37") height per 2 lines, 16 characters/line
Display Update: 100 ms
Process Connection: 1 /8 NPT, internal thread
Electrical Connection: Miniature recessed banana jacks
Housing: Molded, high-impact ABS case, gray
Weight: Base unit: 1.3 kg (2.2 lb) Pressure Module: 0.3kg (0.5lb) each
Dimensions: 200 L x 108 W x 83 mm H (7.88 L x 4.24 W x 3.25" H) nominal
Power Supply: Internal: 9 Vdc batteries (2 required) included External: ac adaptor 9 Vdc, 500 mA
Portable Operation: 30 hours on two 9 Vdc alkaline batteries

PLUG IN PRESSURE MODULES
(psi) RANGES
GAGE PRESSURE
MODEL NO. RANGE (psig)
PCL-MB-005G 0-5
PCL-MB-010G 0-10
PCL-MB-015G 0-15
PCL-MB-020G 0-20
PCL-MB-030G 0-30
PCL-MB-050G 0-50
PCL-MB-100G 0-100
PCL-MB-250G 0-250
PCL-MB-300G 0-300
PCL-MB-500G 0-500
PCL-MB-600G 0-600
PCL-MB-1KG 0-1000
PCL-MB-1.5KG 0-1500
PCL-MB-2KG 0-2000
PCL-MB-2.5KG 0-2500
PCL-MB-3KG 0-3000
PCL-MB-5KG 0-5000
PCL-MB-6KG 0-6000
PCL-MB-7.5KG 0-7500
COMPOUND RANGES
PCL-MB-05BG ±5
PCL-MB-010BG ±10
PCL-MB-15V30BG -15 to 30
PCL-MB-15V60BG -15 to 60
VACUUM RANGES
PCL-MB-10VG 0 to -5
PCL-MB-10VG 0 to -5
PCL-MB-15VG 0 to -15
ABSOLUTE PRESSURE MODULES
MODEL NO. RANGE (psia)
PCL-MB-005A 0-5
PCL-MB-010A 0-10
PCL-MB-015A 0-15
PCL-MB-020A 0-20
PCL-MB-030A 0-30
PCL-MB-050A 0-50
PCL-MB-100A 0-100
PCL-MB-250A 0-250
PCL-MB-300A 0-300
PCL-MB-500A 0-500
PCL-MB-1KA 0-1000
PCL-MB-1.5KA 0-1500
PCL-MB-2KA 0-2000
PCL-MB-2.5KA 0-2500
PCL-MB-3KA 0-3000
PCL-MB-5KA 0-5000
PCL-MB-6KA 0-6000
PCL-MB-7.5KA 0-7500
PLUG IN PRESSURE MODULES
UNIDIRECTIONAL
MODEL NO. RANGE (InH2O)
PCL-MA-0.25WC 0-0.25
PCL-MA-0.5WC 0-0.5
PCL-MA-01WC 0-1.0
PCL-MA-02WC 0-2.0
PCL-MA-03WC 0-3.0
PCL-MA-05WC 0-5.0
PCL-MA-10WC 0-10
PCL-MA-15WC 0-15
PCL-MA-25WC 0-25
PCL-MA-50WC 0-50
PCL-MA-100WC 0-100
PCL-MA-150WC 0-150
PCL-MA-200WC 0-200
BIDIRECTIONAL
PCL-MA-0.125BWC ± 0.125
PCL-MA-0.25BWC ± 0.25
PCL-MA-0.5BWC ± 0.5
PCL-MA-01BWC ± 1.0
PCL-MA-1.5BWC ± 1.5
PCL-MA-2.5BWC ± 2.5
PCL-MA-05BWC ± 5.0
PCL-MA-7.5BWC ± 7.5
PCL-MA-12.5BWC ±12.5
PCL-MA-25BWC ± 25
PCL-MA-50BWC ± 50
PCL-MA-100BWC ± 100
注: The above ordering table contains only a partial list of plug in modules available. For a complete listing please refer to the "Related Links" below.