フリーダイヤル 0120-769-103
Emailjpesales@dwyeromega.com

Ultrasonic Non-Contact Level Measurement - Discontinued

LVU41 and LVU42 Series

Ultrasonic Non-Contact Level Measurement | LVU41 and LVU42 Series

Ultrasonic Non-Contact Level Measurement

スクロールダウンし、全ラインアップをご覧ください

1 year warranty CE
  • Available with RS232 or RS485 Communications
  • Programmable
  • Push-Button Calibration
  • Elimination of Unwanted Echoes
  • Temperature Compensated
  • Field/Bench Calibration
  • Self-Cleaning Sensor Face
  • Non-Volatile Memory (Batteries not Required)

商品説明

The LVU40 is being replaced by the LVU700.

The LVU40 series ultrasonic transmitters are advanced ultrasonic level measurement sensors for liquids. These products continue to meet demanding applications.
The microprocessor-based circuits provide a temperaturecompensated signal for improved accuracy. All models have the ability to filter false echoes produced by peripheral obstructions.
Continuous level measurement can be provided in a range of 0.3 to 18.3 m (1.0 to 60') with several power and programmability options. Point level can also be obtained using a PLC (Industrial Programmable Controller) or one of OMEGA’s CNI process controllers.

SPECIFICATIONS
Accuracy: ±0.25% of max range (in air)
Range: 0.3 to 18.3 m (1 to 60')
Resolution: 6.9 mm (0.270")
Frequency: 45 kHz
Dead Zone Range: 0.3 m (1')
Operating Temperature Range: -40 to 60°C (-40 to 140°F)
Pressure: 1 bar (15 psig max)
Mounting: 3 NPT
Beam Angle: 6 to 12° at -3 dB (model dependent)
Loss of Echo Hold: 30 seconds, 22 mA output
Power Options:
AC: 115 Vac, 60 Hz or 230 Vac, 50 Hz (±20%) 1.7 VA
DC: 12 to 30 Vdc @ 0.07 A, @ 24 Vdc R load = (Vs – 6)/24 mA
Output: 4 to 20 mA or 20 to 4 mA, 6.1 µA resolution; 750 Ω (isolated on 4-wire models only)
Optional: RS232 or RS485 communications port
Fuse: 0.125 A/250 V type
Temperature Compensation: Onboard the sensor
Calibration: Pushbutton or optional programmable
Diagnostics (Echo Profile): Via optional programmable port
Approval: Entela, CE
Conduit Entry: ½ NPT hole (PVC only)
Enclosure: Aluminum with PVC antenna ingress protection [NEMA 4X (IP66)]
Housing Dimensions: 101.6 x 226.1 m (4 x 8.9")
Sensor Diameter: 76.2 mm (3")
注文する (部品番号ビルダーより掲載以外の製品もご選択いただけます)(注文数を入力の上、"カートに追加"をクリックしてください)

他のお客様はこのような商品も購入しています。: このアイコンをクリックすると、このモデルを購入した他のお客様の購入商品リストが表示されます.

部品番号/Desc.
注文数
商品説明
Measurement Range 0.3 to 18.3 m (1 to 60')
  
LVU41-RS232
お問い合せ下さい   
納期: 
 
 
Three-wire 12 to 30Vdc ultrasonic with RS232 communications and Windows software
  
LVU41-RS485
お問い合せ下さい   
納期: 
 
 
Three-wire 12 to 30Vdc ultrasonic with RS485 communications and Windows software
Accessories
Click to expand/minimize a list of what others bought with theDPI32
DPI32
¥40,918 (税込)
(税抜価格 ¥37,198)
納期: 2 週間
 
1/32 DIN panel meter
Click to expand/minimize a list of what others bought with theCNI3233
CNI3233
¥56,452 (税込)
(税抜価格 ¥51,320)
納期: 8 週間
 
1/32 DIN controller with relays
Click to expand/minimize a list of what others bought with thePSR-24S
PSR-24S
お問い合せ下さい   
納期: 
 
 
Regulated power supply, US plug, 90-264 Vac input, 24 Vdc output, 400 mA, screw terminals, UL
注: Comes complete with software and operator’s manual.
Ordering Example: (1) CNI3233 1/32 DIN controller with relays, ¥51,320 
We noticed you are from the US. Visit your local site for regional offers and live support.