カート  |  お問い合わせ  | 
フリーダイヤル 0120-971-357
海外からのお問合せ+81-3-5244-4675

LVR20/30 Series

Liquid Level Transmitters Suitable For Levels to Six Feet | LVR20/30 Series

Liquid Level Transmitters Suitable For Levels to Six Feet

¥107,405 LVR21

1 year warranty RoHS
  • Rugged 316SS Construction
  • 4-20 mA or Resistance Output
  • Immune to Changes of Density and Dielectric
  • 1 /4 " Resolution
レベルスイッチ / レベルセンサ - 関連する商品を探す
(見つからない場合はカスタマーサービスにご連絡ください)

商品説明

The OMEGA™ LVR20 and LVR30 Series continuous liquid level sensors operate on a basic voltage divider network principle. As the float rises, a magnet in the float closes a series of reed switches in sequence which varies the tapped-off portion of the voltage divider resistor network. The LVR20 has the basic voltage divider output—the regulated DC voltage input equals the maximum voltage output. The LVR20 has a nominal 1,200 resistance; thus, with a 10 Vdc supply, 8.3 mA of current are required.

The OMEGA™ DPF52 or DP24-E panel meters can be used to power and display the resistance from the LVR20; when relays are required, the DP25E-A meter can be used. For maximum accuracy, the readout device for the LVR20 should be zero and span adjusted after wiring is completed to compensate for any effects due to the resistance of the lead wires. The LVR20 can also be made intrinsically safe when used with OMEGA’s intrinsic safety barriers and when properly powered. The LVR30 Series is provided with a signal conditioner to provide a 4-20 mA output when powered by 10-30 Vdc. The LVR30 Series cannot be made intrinsically safe.

All LVR30 units are supplied with a J-box with screw terminal connections. All LVR20 units are supplied without a J-box with 24 inches of bare wire coming out of the top of the unit with a 1?2 MNPT conduit connection. All LVR20 and LVR30 Series units can be wired for increasing output with either increasing or decreasing height of liquid; standard output is increasing output with increasing height. For other lengths, adaptor systems are available. They consist of two parts: the LVR-C coupling (2 x 2 FNPT) and an LVR-A pipe nipple (2 x 2 MNPT) of various lengths to change the insertion depth of the LVR20 or LVR30 sensor. When using the adaptors, a zero offset is introduced into the output signal which must be compensated for in the readout device (for example, the mA signal will not go down to 4 mA, nor will the voltage output go down to zero).

Retaining clip pliers are required to remove the float when using the adaptor system.
注文する (部品番号ビルダーより掲載以外の製品もご選択いただけます)(注文数を入力の上、"カートに追加"をクリックしてください)

他のお客様はこのような商品も購入しています。: このアイコンをクリックすると、このモデルを購入した他のお客様の購入商品リストが表示されます.

部品番号/Desc.
注文数
RoHS
商品説明
Isolated 4 to 20 mA Output and J-box
Quick Ship
  
LVR31
¥157,895
納期: 6 週間
RoHS compliant
1 ft 4-20 mA output
Quick Ship
  
LVR33
¥222,300
納期: 6 週間
RoHS compliant
3 ft 4-20 mA output
Quick Ship
  
LVR34
¥252,540
納期: 6 週間
RoHS compliant
4 ft 4-20 mA output
Quick Ship
  
LVR35
¥279,180
納期: 6 週間
RoHS compliant
5 ft 4-20 mA output
Quick Ship
  
LVR36
¥338,760
納期: 6 週間
RoHS compliant
6 ft 4-20 mA output
Voltage Divider (Voltage In = Voltage Out)
Quick Ship
  
LVR21
¥107,405
納期: 6 週間
RoHS compliant
1 ft long indicating length, Voltage Divider, Voltage in = Voltage out
Quick Ship
  
LVR22
¥138,620
納期: 10 週間
RoHS compliant
2 ft long indicating length, Voltage Divider, Voltage in = Voltage out
Quick Ship
  
LVR23
¥168,910
納期: 10 週間
RoHS compliant
3 ft long indicating length, Voltage Divider, Voltage in = Voltage out
Quick Ship
  
LVR24
¥200,160
納期: 6 週間
RoHS compliant
4 ft long indicating length, Voltage Divider, Voltage in = Voltage out
Quick Ship
  
LVR25
¥230,580
納期: 6 週間
RoHS compliant
5 ft long indicating length, Voltage Divider, Voltage in = Voltage out
Quick Ship
  
LVR26
お問い合せ下さい   
納期: 
 
RoHS compliant
6 ft long indicating length, Voltage Divider, Voltage in = Voltage out
Accessories
Quick Ship
  
LVR-A4
¥4,045
納期: 7 週間
RoHS compliancy undetermined
Pipe Nipple, 304 SS, 150 lb fittings, 2 x 2 MNPT, 4" indicating length change
Quick Ship
  
LVR-A6
¥5,470
納期: 7 週間
RoHS compliancy undetermined
Pipe Nipple, 304 SS, 150 lb fittings, 2 x 2 MNPT, 6" indicating length change
Quick Ship
  
LVR-A6
¥5,470
納期: 7 週間
RoHS compliancy undetermined
Pipe Nipple, 304 SS, 150 lb fittings, 2 x 2 MNPT, 6" indicating length change
Quick Ship
  
LVR-A7
¥5,890
納期: 7 週間
RoHS compliancy undetermined
Pipe Nipple, 304 SS, 150 lb fittings, 2 x 2 MNPT, 7" indicating length change
Quick Ship
  
LVR-A9
¥6,815
納期: 7 週間
RoHS compliancy undetermined
Pipe Nipple, 304 SS, 150 lb fittings, 2 x 2 MNPT, 9" indicating length change
Quick Ship
  
LVR-A11
¥7,230
納期: 7 週間
RoHS compliancy undetermined
Pipe Nipple, 304 SS, 150 lb fittings, 2 x 2 MNPT, 11" indicating length change
Quick Ship
  
LVR-A13
¥9,825
納期: 7 週間
RoHS compliancy undetermined
Pipe Nipple, 304 SS, 150 lb fittings, 2 x 2 MNPT, 13" indicating length change
Quick Ship
  
LVR-C
¥14,830
納期: 7 週間
RoHS compliancy undetermined
150 lb 304 SS Coupling, 2 x 2 FNPT
Quick Ship
Click to expand/minimize a list of what others bought with theU24Y175
U24Y175
¥31,500
納期: 2 週間
RoHS compliancy undetermined
24 Vdc, 175 mA Power Supply
Quick Ship
Click to expand/minimize a list of what others bought with theDPI8
DPI8
¥29,403
納期: 2 週間
RoHS compliant
1/8 DIN Display Panel Meter
このサイトの金額はすべて日本円(税抜)で表示しています
注: Units come complete with operator's manual.

LVR20 series is supplied without J-Box.


Ordering Example: (1) DPI8 1/8 DIN display panel meter, ¥29,403  plus (1) LVR22 316 SS level sensor with 2 ft long indicatating length, ¥138,620  plus (1) U24Y175 24 Vdc power supply, ¥31,500, ¥29,403 + 138,620 + 31,500 = ¥199,523