カート  |  お問い合わせ  | 
フリーダイヤル 0120-971-357
海外からのお問合せ+81-3-5244-4675

Mass Flow Controllers with 20+ Gas Select Function

FMA-2600 SERIES

Mass Flow Controllers with 20+ Gas Select Function | FMA-2600  SERIES

Mass Flow Controllers with 20+ Gas Select Function

スクロールダウンし、全ラインアップをご覧ください

1 year warranty CE RoHS
  • 130+ Gas Calibrations, Including: He, O2 , Neon, N2O, N2, Air, Argon, CO, CO2, Methane, Ethane, Propane, Butane, Acetylene, Ethylene, H2
  • Pressure, Temperature, Volumetric & Mass Flow Simultaneously Displayed
  • Easy Operator Push Button Interface
  • NIST Traceability Standard
  • Full Scale Ranges from 0.5 SCCM to 3000 LPM
  • Response Time of 100 milliseconds Typical
  • Turndown Ratio of 100:1 Typical
  • Position Insensitive
  • Accuracy of ±1% Full Scale
  • RS232 Standard
  • No Warm Up Time
質量流量計 (マスフローメータ) - 関連する商品を探す
(見つからない場合はカスタマーサービスにご連絡ください)

商品説明

The FMA-2600A Series mass and volumetric flow controllers use the principle of differential pressure within a laminar flow field to determine and control mass flow rate. A laminar flow element (LFE) inside the meter forces the gas into laminar (streamlined) flow. Inside this region, the Poiseuille equation dictates that the volumetric flow rate be linearly related to the pressure drop. A differential pressure sensor is used to measure the pressure drop along a fixed distance of the LFE. This, along with the viscosity of the gas, is used to accurately determine the volumetric flow rate. Separate absolute temperature and pressure sensors are incorporated and correct the volumetric flow rate to a set of standard conditions. This standardized flow rate is commonly called the mass flow rate and is reported in units such as standard cubic feet per minute (SCFM) or standard liters per minute (SLM).

The controller uses a true proportional valve coupled to the flow body to control flow using the integral PID loop controller. Standard units include a 0 to 5 V output (4 to 20 mA optional) and RS232 communications. The gas-select feature and the setpoints can be adjusted from the front keypad or via RS232 communications. Volumetric flow, mass flow, absolute pressure, and temperature can all be viewed or recorded through the RS232 connection. It is also possible to multi-drop up to 26 units on the same serial connection to a distance of 46 m (150').


SPECIFICATIONS

Accuracy: ±(0.8% of reading + 0.2%FS)
Repeatability: ±0.2% FS
Turndown Ratio: 100:1
Control Response Time: 100 ms
Input Control Signal: 0 to 5 Vdc, RS232
Output Signal: 0 to 5 Vdc, RS232
Optional Input/Outputs: 4 to 20 mA, 0 to 10 Vdc
Operating Temperature: -10 to 50°C (14 to 122°F)
Zero Shift: 0.02%/ATM FS/°C
Span Shift: 0.02%/ATM FS/°C
Humidity Range: 0 to 100% RH, non-condensing
Excess Flow Rate: 2.4% FS
Wetted Materials: Small Valve: 303 & 302 Stainless Steel, FKM, Heat Cured Silicone Rubber, Glass Reinforced Polyphenylene Sulfide, Heat Cured Epoxy, Aluminum, Gold, Brass, 430FR Stainless Steel, Silicon, Glass. Large Valve: 303 & 302 Stainless Steel, FKM, Heat Cured Silicone Rubber, Glass Reinforced Polyphenylene Sulfide, Heat Cured Epoxy, Aluminum, Gold, 416 Stainless Steel, Silicon, Glass.
-LSS (Option):316LSS, 303SS, 430FRSS, Perfluoroelastomer standard, FKM, EPDM, Buna, Neoprene Maximum Pressure: Mass Flow Controllers: 145 psig
To Use in Volumetric Mode: Near atmosphere, 15 psig recommended maximum. Volumetric flowmeters and controllers not certified for accuracy at mass flow rates above the rated flow range of the meter. They are designed for near atmospheric pressure conditions only. The recommended maximum operating pressure is 15 psig Minimum Differential Pressure Required:
5 SLM and under: 5 psid; 10 to 250 SLM:
15 psid; 500 SLM: 5 psid; 1500 SLM: 10 psid
Supply Current: 0.250 A for 20 SLM and under; 0.75 A for 50 SLM and above (typical)
Supply Voltage: 12 to 30 Vdc for units
20 SLM and smaller; 24 to 30 Vdc for units
50 SLM and larger
Electrical Connections: 8-pin circular mini DIN
注文する (部品番号ビルダーより掲載以外の製品もご選択いただけます)(注文数を入力の上、"カートに追加"をクリックしてください)

他のお客様はこのような商品も購入しています。: このアイコンをクリックすると、このモデルを購入した他のお客様の購入商品リストが表示されます.

部品番号/Desc.
注文数
RoHS
商品説明
Mass Flow Controllers
Quick Ship
  
FMA-2601A
¥439,200
納期: 6 週間
RoHS compliant
0.5 SCCM, 10 to 32 UNF Thread
Quick Ship
  
FMA-2601A-I
¥451,800
納期: 6 週間
RoHS compliant
0.5 SCCM, 10 to 32 UNF Thread, one 4 to 20 mA output
Quick Ship
  
FMA-2602A
¥439,200
納期: 6 週間
RoHS compliant
1 SCCM, 10 to 32 UNF Thread
Quick Ship
  
FMA-2602A-I
¥451,800
納期: 6 週間
RoHS compliant
1 SCCM, 10 to 32 UNF Thread, one 4 to 20 mA output
Quick Ship
  
FMA-2614A
¥390,600
納期: 6 週間
RoHS compliant
2 SCCM, 10 to 32 UNF Thread
Quick Ship
  
FMA-2614A-I
¥405,000
納期: 6 週間
RoHS compliant
2 SCCM, 10 to 32 UNF Thread, one 4 to 20 mA output
Quick Ship
  
FMA-2615A
¥390,600
納期: 6 週間
RoHS compliant
5 SCCM, 10 to 32 UNF Thread
Quick Ship
  
FMA-2615A-I
¥405,000
納期: 6 週間
RoHS compliant
5 SCCM, 10 to 32 UNF Thread, one 4 to 20 mA output
Quick Ship
  
FMA-2603A
¥341,100
納期: 6 週間
RoHS compliant
10 SCCM, 10 to 32 UNF Thread
Quick Ship
  
FMA-2603A-I
¥354,600
納期: 6 週間
RoHS compliant
10 SCCM, 10 to 32 UNF Thread, one 4 to 20 mA output
Quick Ship
  
FMA-2616A
¥341,100
納期: 6 週間
RoHS compliant
20 SCCM, 10 to 32 UNF Thread
Quick Ship
  
FMA-2616A-I
¥354,600
納期: 6 週間
RoHS compliant
20 SCCM, 10 to 32 UNF Thread, one 4 to 20 mA output
Quick Ship
  
FMA-2604A
¥341,100
納期: 6 週間
RoHS compliant
50 SCCM, 10 to 32 UNF Thread
Quick Ship
  
FMA-2604A-I
¥354,600
納期: 6 週間
RoHS compliant
50 SCCM, 10 to 32 UNF Thread, one 4 to 20 mA output
Quick Ship
  
FMA-2617A
¥291,600
納期: 4 週間
RoHS compliant
100 SCCM, 1/8 FNPT connection
Quick Ship
  
FMA-2617A-I
¥304,200
納期: 4 週間
RoHS compliant
100 SCCM, 1/8 FNPT, one 4 to 20 mA output
Quick Ship
  
FMA-2618A
¥291,600
納期: 4 週間
RoHS compliant
200 SCCM, 1/8 FNPT connection
Quick Ship
  
FMA-2618A-I
¥304,200
納期: 4 週間
RoHS compliant
200 SCCM, 1/8 FNPT, one 4 to 20 mA output
Quick Ship
  
FMA-2619A
¥291,600
納期: 4 週間
RoHS compliant
500 SCCM, 1/8 FNPT connection
Quick Ship
  
FMA-2619A-I
¥304,200
納期: 4 週間
RoHS compliant
500 SCCM, 1/8 FNPT, one 4 to 20 mA output
Quick Ship
  
FMA-2620A
¥291,600
納期: 2 週間
RoHS compliant
1 SLM, 1/8 FNPT
Quick Ship
  
FMA-2620A-I
¥304,200
納期: 4 週間
RoHS compliant
1 SLM, 1/8 FNPT, one 4 to 20 mA output
Quick Ship
  
FMA-2605A
¥291,600
納期: 4 週間
RoHS compliant
2 SLM, 1/8 FNPT
Quick Ship
  
FMA-2605A-I
¥304,200
納期: 4 週間
RoHS compliant
2 SLM, 1/8 FNPT, one 4 to 20 mA output
Quick Ship
  
FMA-2606A
¥291,600
納期: 4 週間
RoHS compliant
5 SLM, 1/8 FNPT
Quick Ship
  
FMA-2606A-I
¥304,200
納期: 4 週間
RoHS compliant
5 SLM, 1/8 FNPT, one 4 to 20 mA output
Quick Ship
  
FMA-2607A
¥291,600
納期: 4 週間
RoHS compliant
10 SLM, 1/8 FNPT
Quick Ship
  
FMA-2607A-I
¥304,200
納期: 4 週間
RoHS compliant
10 SLM, 1/8 FNPT, one 4 to 20 mA output
Quick Ship
  
FMA-2608A
¥341,100
納期: 4 週間
RoHS compliant
20 SLM, 1/8 FNPT
Quick Ship
  
FMA-2608A-I
¥354,600
納期: 4 週間
RoHS compliant
20 SLM, 1/8 FNPT, one 4 to 20 mA output
Quick Ship
  
FMA-2609A
¥397,800
納期: 3 週間
RoHS compliant
50 SLM, 1/4 FNPT
Quick Ship
  
FMA-2609A-I
¥411,300
納期: 4 週間
RoHS compliant
50 SLM, 1/4 FNPT, one 4 to 20 mA output
Quick Ship
  
FMA-2610A
¥441,900
納期: 2 週間
RoHS compliant
100 SLM, 1/4 FNPT
Quick Ship
  
FMA-2610A-I
¥456,300
納期: 6 週間
RoHS compliant
100 SLM, 1/4 FNPT, one 4 to 20 mA output
Quick Ship
  
FMA-2611A
¥486,000
納期: 6 週間
RoHS compliant
250 SLM, 1/2 FNPT
Quick Ship
  
FMA-2611A-I
¥497,700
納期: 8 週間
RoHS compliant
250 SLM, 1/2 FNPT, one 4 to 20 mA output
Quick Ship
  
FMA-2612A
¥512,100
納期: 6 週間
RoHS compliant
500 SLM, 3/4 FNPT
Quick Ship
  
FMA-2612A-I
¥523,800
納期: 7 週間
RoHS compliant
500 SLM, 3/4 FNPT, one 4 to 20 mA output
Quick Ship
  
FMA-2613A
¥580,500
納期: 6 週間
RoHS compliant
1000 SLM, 3/4 FNPT
Quick Ship
  
FMA-2613A-I
¥594,900
納期: 6 週間
RoHS compliant
1000 SLM, 3/4 FNPT, one 4 to 20 mA output
Quick Ship
  
FMA-2621A
¥689,400
納期: 6 週間
RoHS compliant
1500 SLM, 3/4 FNPT
Quick Ship
  
FMA-2621A-I
¥702,000
納期: 8 週間
RoHS compliant
1500 SLM, 3/4 FNPT, one 4 to 20 mA output
Quick Ship
  
FMA-2622A
¥790,200
納期: 6 週間
RoHS compliancy undetermined
2000 SLM, 3/4 FNPT
Quick Ship
  
FMA-2622A-I
¥802,800
納期: 6 週間
RoHS compliancy undetermined
2000 SLM, 3/4 FNPT, one 4 to 20 mA output
Quick Ship
  
FMA-2623A
¥893,700
納期: 6 週間
RoHS compliancy undetermined
3000 SLM, 1 1/4 FNPT
Quick Ship
  
FMA-2623A-I
¥906,300
納期: 6 週間
RoHS compliancy undetermined
3000 SLM, 1 1/4 FNPT, one 4 to 20 mA output
Volumetric Flow Controllers
Quick Ship
  
FVL-2602A
お問い合せ下さい   
納期: 
 
RoHS compliant
1 SCCM, 10-32 thread connection
Accessories
Quick Ship
Click to expand/minimize a list of what others bought with theFMA1600-C1
FMA1600-C1
¥8,770
納期: 2 週間
RoHS compliant
Replacement 1.8M (6') 8 pin male Mini-DIN single ended, cable connector
Quick Ship
  
FMA1600-C1-25 FT
¥15,790
納期: 2 週間
RoHS compliant
7.62M (25') 8 pin male Mini-DIN single ended, cable connector
Quick Ship
  
FMA1600-C2
¥10,100
納期: 2 週間
RoHS compliant
1.8M (6') 8 pin male Mini-DIN double ended, cable connector
Quick Ship
  
FMA1600-C2-25 FT
¥18,725
納期: 2 週間
RoHS compliancy undetermined
7.62M (25') 8 pin male Mini-DIN double ended, cable connector
Quick Ship
Click to expand/minimize a list of what others bought with theFMA1600-C3
FMA1600-C3
¥10,303
納期: 4 週間
RoHS compliant
1.8M (6') 8 pin male Mini-DIN to DB9 female adapter
Quick Ship
  
FMA1600-CRA
¥10,100
納期: 4 週間
RoHS compliancy undetermined
1.8M (6') 8 pin male right angle Mini-DIN single ended cable connector
Quick Ship
  
FMA1600-MDB
¥54,160
納期: 2 週間
RoHS compliancy undetermined
Multi Drop Box
Quick Ship
Click to expand/minimize a list of what others bought with theFMA1600-PSU
FMA1600-PSU
¥15,790
納期: 2 週間
RoHS compliancy undetermined
24 Vdc universal power supply
Quick Ship
  
FMA1600-E2
お問い合せ下さい   
納期: 
 
RoHS compliant
220VAC to 24VDC Power Supply for 50 LPM or greater
Tube Fitting Adapters for Threaded to 10/32
Quick Ship
  
FTNY-K210BN
¥890
納期: 6 週間
RoHS compliant
Nylon Body, TUBE ID 1/16" TO MALE 10-32UNF
Quick Ship
  
FTPP-K210NP
¥890
納期: 2 週間
RoHS compliant
Polypropylene Body, TUBE ID 1/16" TO MALE 10-32UNF
Quick Ship
  
FTNY-K230BN
¥890
納期: 6 週間
RoHS compliant
Nylon Body, TUBE ID 1/8" TO MALE 10-32UNF
Quick Ship
  
FTPP-K230NP
¥890
納期: 6 週間
RoHS compliant
Polypropylene Body, TUBE ID 1/8" TO MALE 10-32UNF
このサイトの金額はすべて日本円(税抜)で表示しています
注: Comes complete with 24 Vdc universal power supply, 1.8m (6') cable, 8-pin male Mini- DIN connector, operator's manual, and NIST certificate.

Standard units are calibrated to air @ 5 psig for 0 to 1 LPM, 15 psig for 2 to 10 LPM, 30 psig for 20 to 100 LPM, and 50 psig for 200 LPM and greater.

For custom calibrations, add "-(*)" to the model number, no additional cost. *Specify gas, and inlet/outlet or backpressure for custom calibrations.

Calibrations done at ambient (25C/77F) temperature only.

To replace the standard RS232 communications with RS485, add suffix "-RS485" to the model number, add $120 to the price.

Standard input is 0-5V, for optional 4-20 mA input add suffix "-IN" to the model number, no additional cost.

Standard output is scaled to the mass flow rate. For volumetric flow rate as standard output add suffix "-VOL" to the model number. For "-VOL" controllers the control loop is set to volumetric as standard.

Optional secondary output are scaled the same as the primary output scale. For an alternate output scale add suffix "-V2T" for voltage scaled for temperature, "-I2T" for current scaled for temperature, "-V2P" for voltage scaled for pressure or "-I2P" for current scaled for pressure, no additional cost.

For units scaled in SCFH, add suffix "-SCFH" to model number, no additional cost. Please specify the desired range in SCFH.

For totalizer option, add suffix "-TOT" to the model number, add $120 to the price. Please specify resolution.

This is a 6-digit counter. Examples: For totalizing in liters with 1/100 liter resolution, the max count would be 9999.99. For totalizing in liters with 1 liter resolution, the max count would be 999999.

For a Remote Display, add suffix "-RD-*FT" to the model number, add $210 to the price. Replace the * in the suffix with the required length in whole feet, the maximum length is 3.6576 m (12'). Please note the optimum distance in feet is between 2.7 to 3 m (9 to 10').

Ethernet/IP, DeviceNet, Modbus and Profibus communications are also available for an additional charge.


Ordering Example: (1) FMA-2601A-I2 10-32 Thread Mass Gas Flow Controller with optional second channel output of 4-20mA, ¥465,300

部品番号ビルダー

下記から仕様構成を選択し、ご注文ください
以下からオプションを選択:


(1) Flow Range :
01 : 0.5 SCCM
02 : 1 SCCM
14 : 2 SCCM
15 : 5 SCCM
03 : 10 SCCM
16 : 20 SCCM
04 : 50 SCCM
17 : 100 SCCM
18 : 200 SCCM
19 : 500 SCCM
20 : 1 SLM
05 : 2 SLM
06 : 5 SLM
07 : 10 SLM
08 : 20 SLM
09 : 50 SLM
10 : 100 SLM
11 : 250 SLM
12 : 500 SLM
13 : 1000 SLM
21 : 1500 SLM
22 : 2000 SLM
23 : 3000 SLM

(2) Output :
オプション選択がない場合 : None
-I : 4 to 20 mA output
-I2 : Two 4 to 20 mA outputs
-V2 : Two 0 to 5V Outputs
-I2T : Two 4 to 20 mA outputs second output for temperature
-V2T : Two 0 to 5V outputs second output for temperature
-I2P : Two 4 to 20 mA outputs second output for pressure
-V2P : Two 0 to 5V outputs second output for pressure
-VOL : Volumetric flow rate as standard output

(3) Integrated positive shut-off valve :
オプション選択がない場合 : Standard
-P : Integrated positive shut-off valve (only available on models up to 20 SLM)

(4) Input :
オプション選択がない場合 : 0 to 5V
-IN : 4 to 20 mA input

(5) RS485 :
オプション選択がない場合 : RS232
-RS485 : RS485

(6) SCFH :
オプション選択がない場合 : Standard
-SCFH : Units scaled in SCFH

(7) Totalizer :
オプション選択がない場合 : Standard
-TOT : Totalizer
注: 有効な部品番号については、「商品仕様(PDF)」を参照ください。
ご不明な場合は、カスタマーサービス(0120-040-572 もしくは esales@jp.omega.com)へお問合せください。