Conductivity, Resistivity or TDS Controller

CDCN-961

Conductivity, TDS and Resistivity Controller | TDS Controller | CDCN-961

¥289,483 CDCN-961

1 year warranty CE
  • Monitors conductivity, resistivity and TDS in process solutions and water applications.
  • Menu-Driven Programming
  • NEMA 4X (IP65) Protection
  • Programmable High/Low, and Alarm Relays
  • Dual Backlit LCD
  • Calibration Reminder Via Alarm Relay Setting
  • Isolated 0.4 to 20 mA Output
  • RS485 Output
  • Applications
  • Waste Water Treatment
  • Power Plants
  • Thermo-Electric Plants
  • Pharmaceutical
  • Photographic Industries
  • Soft Drink Industries

商品説明

The CDCN-961 conductance, resistance or total dissolved solids (TDS) controller is designed for inline monitoring of process solutions and water applications.

The CDCN-961 has simple menu driven programming for easy setup. Available relays can be programmed for control, alarm or as a calibration reminder. The transmitter output is also programmable from the keypad eliminating the need for potentiometer or dip-switch settings. The calibration function automatically recognizes the buffer solution resulting in a simple and straight forward system calibration.

Specifications
Conductivity Range:

    0.000 to 3.000, 30.00, 300.0 µS/cm
    0.000 to 3.000, 30.00, 300.0 mS/cm
Resistivity Range:
    0.3 to 30.0 MΩcm
    3 to 300 MΩcm
TDS Range:
    0.000 to 3.000, 30.00, 300.0 ppm
    0.000 to 3.000, 30.00, 300.0 ppt
Resolution:
    0.001/0.01/0.1 µS/cm
    0.001/0.01/0.1 mS/cm
    0.1 MΩcm
Accuracy: ±1% FS
Temperature Range: -0.5 to 130°C (31.1 to 266°F)
Temperature Resolution /Accuracy: 0.1°C/ ±0.5°C
Cell Constant: K = 0.01, 0.1, 1, 10
Line Resistance Compensation: 0.0 to 20.0 Ω
Temperature Sensor: Pt1000
Signal Output/Load: 0/4 to 20 mA/600Ω
Output Interface: RS485
Relay Specification: 3 SPST/250V 1A
Control Hysteresis Band: 0.1 to 10% FS
Frequency of Cleaning Time: 1 to 999 hours 1 to 999 seconds
EMC Standard: EN 50081-1/EN 50082-1
Operation Temperature: -10 to 50°C (14 to 122°F)
Operation Humidity: 10 to 95%
Housing: NEMA 4X (IP65)
Dimensions: 100 W x 108 L x 136 Dia mm (3.93 x 4.25 x 5.35")
Panel Cutout: 93.5 L x 93.5 W mm (3.68 x 3.68")
Weight: 1650 g (58 oz)
Accessory:
    Conductivity Electrode: K=1.0
    Material: PPS/graphite
    Test Range: 0 to 50.0 mS/cm
    Temperature Range: 0 to 80°C (32 to 176°F)
    Temperature System: Pt1000
    Cable: 5 m (16.4')
注文する (部品番号ビルダーより掲載以外の製品もご選択いただけます)(注文数を入力の上、"カートに追加"をクリックしてください)

他のお客様はこのような商品も購入しています。: このアイコンをクリックすると、このモデルを購入した他のお客様の購入商品リストが表示されます.

部品番号/Desc.
注文数
商品説明
  
CDCN-961
¥318,431 (税込)
(税抜価格 ¥289,483)
納期: 4 週間
 
Conductivity resistivity TDS controller
Acessories
  
CDE-961
¥142,555 (税込)
(税抜価格 ¥129,595)
納期: 2 週間
 
Replacement probe/cell for CDCN-961 controller
Click to expand/minimize a list of what others bought with theCDSA-10
CDSA-10
¥15,586 (税込)
(税抜価格 ¥14,169)
納期: 2 週間
 
10 µmho/cm conductivity solution, 940 ml bottle
Click to expand/minimize a list of what others bought with theCDSA-45
CDSA-45
¥3,830 (税込)
(税抜価格 ¥3,482)
納期: 3 週間
 
45 µS/cm conductivity solution
注: Comes complete with probe/cell and operator’s manual.
We noticed you are from the US. Visit your local site for regional offers and live support.